MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/1471-0528.17872

Медицинская библиотека · BJOG : an international journal of obstetrics and gynaecology · 2024

Accuracy of sonographic lower segment thickness and prediction of vaginal birth after caesarean in a resourced-limited setting; Prospective study.

Adu-Takyi Charles, Munazzah Rafique, Owusu Yaw Gyanteh, Owusu-Bempah Atta, Arhin Bernard, Opare-Addo Henry Sakyi, Peprah Amponsah, Collins Sally L, Adu-Bredu Theophilus

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To assess the accuracy of ultrasound measurement of the lower uterine segment (LUS) thickness against findings at laparotomy, and to investigate its correlation with the success rate of vaginal birth after one previous caesarean delivery (CD) in a resource-limited setting.

DESIGN

Prospective study.

SETTING

Obstetrics and Gynaecology department in a tertiary hospital in Ghana.

POPULATION: Women with one previous CD undergoing either a trial of labour (TOLAC) or elective CD.

METHODS

Myometrial lower uterine segment thickness (mLUS) and full lower uterine segment thickness (fLUS) were measured with transvaginal ultrasound (TVUS). The women were managed according to local protocols with the clinicians blinded to the ultrasound measurements. The LUS was measured intraoperatively for comparison with ultrasound measurements.

MAIN OUTCOME MEASURES: Lower uterine segment findings at laparotomy, successful vaginal birth.

RESULTS

A total of 311 pregnant women with one previous CD were enrolled; 147 women underwent elective CD and 164 women underwent a TOLAC. Of the women that underwent TOLAC, 96 (58.5%) women had a successful vaginal birth. The mLUS was comparable to the intraoperative measurement in the elective CD group with LUS thickness <5 mm (bias of 0.01, 95% CI -0.10 to 0.12 mm) whereas fLUS overestimated LUS <5 mm (bias of 0.93, 95% CI 0.80-1.06 mm). Successful vaginal birth rate correlated with increasing mLUS values (odds ratio 1.30, 95% CI 1.03-1.64). Twelve cases of uterine defect were recorded. LUS measurement ≤2.0 mm was associated with an increased risk of uterine defects with a sensitivity of 91.7% (95% CI 61.5-99.8%) and specificity of 81.8% (95% CI 75.8-86.8%).

CONCLUSION

Accurate TVUS measurement of the LUS is technically feasible in a resource-limited setting. This approach could help in making safer decisions on mode of birth in limited-resource settings.

Для цитирования: Adu-Takyi Charles, Munazzah Rafique, Owusu Yaw Gyanteh, Owusu-Bempah Atta, Arhin Bernard, Opare-Addo Henry Sakyi, Peprah Amponsah, Collins Sally L, Adu-Bredu Theophilus. Accuracy of sonographic lower segment thickness and prediction of vaginal birth after caesarean in a resourced-limited setting; Prospective study.. BJOG : an international journal of obstetrics and gynaecology. 2024. DOI: 10.1111/1471-0528.17872.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.