m+Medelevator.RU
← Поиск публикаций
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2025

Rapid and sensitive detection of Candida albicans using nystatin-functionalized magnetic spheres.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhao Zhen-Yu, Che Ya-Ning, Huang Qian, Yang Han-Wen, Wang Xian-Hua, Dong Lin-Yi

Аннотация

Candida albicans is the leading cause of invasive fungal disease; candidemia carries 30-40 % mortality. It commonly colonizes human mucosa as a commensal, but immunosuppression or disrupted microbiota enables opportunistic infection. Therefore, rapid, reliable diagnostics are vital to improve public health. In this study, a magnetic solid-phase microextraction (MSPE) technique based on nystatin-functionalized magnetic nanoparticles (Fe₃O₄@NYS) was developed to achieve the dual objectives of efficiently enriching C. albicans rapidly and extracting its deoxyribonucleic acid (DNA). Optimization of capture conditions enabled rapid enrichment of C. albicans with a maximum recovery rate of approximately 90 %. Subsequent to the capture of C. albicans, DNA extraction was performed on the Fe₃O₄@NYS-C. albicans complexes. Notably, Fe₃O₄@NYS facilitated the extraction of a substantial quantity of DNA, with the extraction yield reaching 1200 ng/mg. Therefore, the integration of DNA extraction with quantitative polymerase chain reaction (qPCR) technology enables sensitive and specific detection of C. albicans in real samples. The strategy demonstrated excellent linearity within the concentration range of 4.20 × 102 to 4.20 × 107 CFU mL-1 for C. albicans. The high sensitivity and accuracy of this method were confirmed in honey samples, showcasing a limit of detection (LOD) 420 CFU mL-1, recoveries between 98.1 % and 99.8 %, and relative standard deviations (RSD) not exceeding 2.51 %. This method presents an innovative strategy for point-of-care clinical diagnosis, disease surveillance, and biosafety management, demonstrating substantial potential for the efficient isolation of DNA from complex biological matrices.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты