OBJECTIVE

To revive the use of the Kahn Uterine Trigger Cannula to overcome limitations associated with technical difficulties during hysterosalpingography (HSG) using the disposable balloon HSG catheter.

METHOD: A case series was conducted of 17 patients who encountered technically difficult or incomplete HSG study while using a disposable HSG balloon catheter, also leading to false-positive findings. Nine patients underwent a repeat HSG using a Kahn Uterine Trigger Cannula (Group 1). Eight patients underwent diagnostic laparoscopy and tubal perfusion testing using a Kahn Uterine Trigger Cannula (Group 2). The findings for each group in comparison to their initial HSG results using the disposable balloon HSG catheter are described.

RESULTS

All patients were noted to have patent fallopian tubes using a Kahn Uterine Trigger Cannula on repeat HSG or tubal perfusion testing during laparoscopy.

CONCLUSION

Providers who perform HSG studies should be familiar with the value of a Kahn Uterine Trigger Cannula when the traditional use of disposable HSG balloon catheter fails due to technical difficulty or incomplete study. The use of the Kahn Uterine Trigger Cannula in such situations can prevent inaccurate assessment and unnecessary interventions.

Для цитирования: Youssef Youssef, Raju Rubin, Sanya Rahima, Abuzeid Omar, Hebert John, Abuzeid Mostafa. Perfecting hysterosalpingography: Limitations to the use of disposable balloon catheter and its solution.. International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics. 2022. DOI: 10.1002/ijgo.14118.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.