Journal of the American Veterinary Medical Association · 1999
Combined cycloablation and gonioimplantation for treatment of glaucoma in dogs: 18 cases (1992-1998).
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Bentley E, Miller P E, Murphy C J, Schoster J V
Аннотация
OBJECTIVE: To evaluate a combined cycloablative and gonioimplantation technique for treatment of glaucoma in dogs.
DESIGN: Retrospective study.
ANIMALS: 18 adult dogs with glaucoma.
PROCEDURE: Medical records of dogs that received a valved gonioimplant and a cyclodestructive procedure (cyclocryoablation or diode laser cyclophotocoagulation) during a 6-year period were reviewed. Retention of vision and intraocular pressure control were assessed, as well as number and nature of complications.
RESULTS: 19 eyes of 18 dogs received a valved gonioimplant and either cyclocryoablation (n = 12) or diode laser cyclophotocoagulation (7). At > or = 1 year after surgery, 11 of 19 eyes had vision and 14 of 19 eyes had intraocular pressure < 25 mm Hg. Two dogs (2 eyes) were lost to follow-up 3 and 6 months after surgery. Despite the alternative route for aqueous humor flow created by the gonioimplant, 7 eyes had increased intraocular pressure (27 to 61 mm Hg) < 24 hours after surgery. Other complications included excessive intraocular fibrin, focal retinal detachment, corneal ulcer, retinal hemorrhage, cataract, and implant migration.
CONCLUSIONS AND CLINICAL RELEVANCE: Combined cycloablation and gonioimplantation appears to be a promising technique for retention of vision and control of intraocular pressure in dogs with glaucoma.
DESIGN: Retrospective study.
ANIMALS: 18 adult dogs with glaucoma.
PROCEDURE: Medical records of dogs that received a valved gonioimplant and a cyclodestructive procedure (cyclocryoablation or diode laser cyclophotocoagulation) during a 6-year period were reviewed. Retention of vision and intraocular pressure control were assessed, as well as number and nature of complications.
RESULTS: 19 eyes of 18 dogs received a valved gonioimplant and either cyclocryoablation (n = 12) or diode laser cyclophotocoagulation (7). At > or = 1 year after surgery, 11 of 19 eyes had vision and 14 of 19 eyes had intraocular pressure < 25 mm Hg. Two dogs (2 eyes) were lost to follow-up 3 and 6 months after surgery. Despite the alternative route for aqueous humor flow created by the gonioimplant, 7 eyes had increased intraocular pressure (27 to 61 mm Hg) < 24 hours after surgery. Other complications included excessive intraocular fibrin, focal retinal detachment, corneal ulcer, retinal hemorrhage, cataract, and implant migration.
CONCLUSIONS AND CLINICAL RELEVANCE: Combined cycloablation and gonioimplantation appears to be a promising technique for retention of vision and control of intraocular pressure in dogs with glaucoma.