American heart journal · 2024
The relative merits of using a high-sensitivity cardiac Troponin T assay compared to a nonhigh-sensitivity troponin T assay after noncardiac surgery.
СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Borges Flavia K, Sessler Daniel I, Tiboni Maria, Patel Ameen, LeManach Yannick, Heels-Ansdell Diane, Srinathan Sadeesh, Wang Chew Yin, Chow Clara, Duceppe Emmanuelle, Kavsak Peter, Ofori Sandra N, Pettit Shirley, Berwanger Otavio, Kurz Andrea, Turan Alparslan, Tonelli Ana Claudia, Devereaux P J, VISION Study Investigators
Аннотация
INTRODUCTION: Troponin elevation after noncardiac surgery is associated with an elevated risk of 30-day mortality. Little is known about relative merit of using a high-sensitivity Troponin T (hsTnT), the fifth-generation assay, vs the nonhigh sensitivity Troponin T (non-hsTnT), the fourth-generation assay, in the noncardiac surgery setting. We aimed to identify whether hsTnT can identify additional patients at risk that would have gone undetected with non-hsTnT measurement.
METHODS: The VISION Study included 40,004 noncardiac surgery patients with postoperative troponin measurements. Among them, 1,806 patients had both fourth-generation non-hsTnT and fifth-generation hsTnT concomitant measurements (4,451 paired results). We compared the absolute concentrations, the timing, and the impact of different thresholds on predicting 30-day major cardiovascular complications (composite of death, nonfatal cardiac arrest, coronary revascularization, and congestive heart failure).
RESULTS: Based on the manufacturers' threshold of 14 ng/L, 580 (32.1%) patients had postoperative hsTnT concentrations greater than the threshold, while their non-hsTnT concentrations were below the manufacturer's threshold. These 580 patients had higher risk of major cardiovascular events (OR 2.33; CI 95% 1.04-5.23; P = .049) than patients with hsTnT concentrations below the manufacturer threshold. Among patients with myocardial injury after noncardiac surgery, only 50% would be detected by the fourth-generation non-hsTnT assay at 6 to 12 hours postoperative as compared to 85% with the fifth-generation hsTnT assay (P-value < .001).
CONCLUSIONS: Within the first 3 postoperative days, fifth-generation hsTnT identified at least 1 in 3 patients with troponin elevation that would have gone undetected by fourth-generation non-hsTnT using published thresholds in this setting. Furthermore, fifth-generation hsTnT identified patients with an elevation earlier than fourth-generation non-hsTnT, indicating potential to improve postoperative risk stratification.
METHODS: The VISION Study included 40,004 noncardiac surgery patients with postoperative troponin measurements. Among them, 1,806 patients had both fourth-generation non-hsTnT and fifth-generation hsTnT concomitant measurements (4,451 paired results). We compared the absolute concentrations, the timing, and the impact of different thresholds on predicting 30-day major cardiovascular complications (composite of death, nonfatal cardiac arrest, coronary revascularization, and congestive heart failure).
RESULTS: Based on the manufacturers' threshold of 14 ng/L, 580 (32.1%) patients had postoperative hsTnT concentrations greater than the threshold, while their non-hsTnT concentrations were below the manufacturer's threshold. These 580 patients had higher risk of major cardiovascular events (OR 2.33; CI 95% 1.04-5.23; P = .049) than patients with hsTnT concentrations below the manufacturer threshold. Among patients with myocardial injury after noncardiac surgery, only 50% would be detected by the fourth-generation non-hsTnT assay at 6 to 12 hours postoperative as compared to 85% with the fifth-generation hsTnT assay (P-value < .001).
CONCLUSIONS: Within the first 3 postoperative days, fifth-generation hsTnT identified at least 1 in 3 patients with troponin elevation that would have gone undetected by fourth-generation non-hsTnT using published thresholds in this setting. Furthermore, fifth-generation hsTnT identified patients with an elevation earlier than fourth-generation non-hsTnT, indicating potential to improve postoperative risk stratification.