MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15910199241246018

Медицинская библиотека · Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024

FRED X flow diverter for the treatment of intracranial aneurysms: Two-center experience and mini-review of the literature.

Goertz Lukas, Styczen Hanna, Siebert Eberhard, Li Yan, Schlamann Marc, Forsting Michael, Bohner Georg, Deuschl Cornelius, Kabbasch Christoph

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

ObjectiveThe flow re-direction endoluminal device (FRED) is a safe and effective treatment option for intracranial aneurysms. The novel FRED X features an antithrombotic surface coating ("X Technology") on an otherwise unmodified stent design. This two-center study evaluates the clinical safety and efficacy of FRED X and compares it to the literature.MethodsConsecutive patients treated between 2020 and 2023 were retrospectively reviewed for aneurysm characteristics, procedural details and complications, and angiographic outcomes. A mini-review of the literature for FRED X clinical trials was performed and results were pooled using a random effects model.ResultsThirty-four patients (mean age 56 years) were treated for 34 aneurysms. The mean aneurysm size was 7.7 ± 5.0 mm, 7 (21%) were ruptured, 6 (18%) were recurrent after previous treatment, 11 (32.3%) were located in the posterior circulation, and 4 (12.5%) had non-saccular morphology. All procedures were technically successful and no balloon angioplasty was required. There was 1 (2.9%) symptomatic complication (a transient ischemic attack) and no procedural morbidity or mortality. Technical asymptomatic events included 1 procedural stent occlusion that was reopened with thrombectomy and 3 cases of vasospasm. Complete and adequate occlusion rates were 68% (19/28) and 89% (25/28) at a mean follow-up time of 6 months, respectively. The results of this study are comparable to previous FRED X studies.ConclusionsThe results demonstrate a high feasibility and procedural safety of the FRED X with adequate mid-term occlusion rates. Long-term and comparative studies are needed to evaluate the full potential of the FRED X.

Для цитирования: Goertz Lukas, Styczen Hanna, Siebert Eberhard, Li Yan, Schlamann Marc, Forsting Michael, Bohner Georg, Deuschl Cornelius, Kabbasch Christoph. FRED X flow diverter for the treatment of intracranial aneurysms: Two-center experience and mini-review of the literature.. Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences. 2024. DOI: 10.1177/15910199241246018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.