MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.diagmicrobio.2009.10.010

Медицинская библиотека · Diagnostic microbiology and infectious disease · 2010

Detection of Histoplasma capsulatum DNA in human samples by real-time polymerase chain reaction.

Simon Stephane, Veron Vincent, Boukhari Rachida, Blanchet Denis, Aznar Christine

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The main aim of our study was to determine the added value of real-time polymerase chain reaction (PCR) for the diagnosis of Histoplasma capsulatum in routine biologic practice. No amplification signal was observed with the 18 non-H. capsulatum strains used to test the specificity of the protocol. The sensitivity threshold of the real-time PCR assay was about 10 fg of H. capsulatum DNA per microliter, tested with a 10-fold serial dilution of the positive control. We analyzed 348 human samples submitted for the routine diagnosis of systemic mycosis. Real-time PCR using the TaqMan system was evaluated against direct microscopic examination and culture. Among the 341 samples without PCR inhibition (n = 7), 66 tested positive by culture, whereas 74 tested positive by real-time PCR. Sensitivity of the real-time PCR assay was estimated at 95.4% and specificity at 96.0% with respect to culture, widely considered to be the gold standard method; however, the molecular approach in fact produced better sensitivity and specificity results. Moreover, for the 38 samples that tested negative by direct examination but positive by culture, the culture method took a mean of 31 days longer than the PCR method to generate results. The protocol presented here may be very useful for improving routine histoplasmosis diagnosis.

Для цитирования: Simon Stephane, Veron Vincent, Boukhari Rachida, Blanchet Denis, Aznar Christine. Detection of Histoplasma capsulatum DNA in human samples by real-time polymerase chain reaction.. Diagnostic microbiology and infectious disease. 2010. DOI: 10.1016/j.diagmicrobio.2009.10.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.