MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinph.2015.09.129

Медицинская библиотека · Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2015

A signal-to-noise-ratio-based analysis of multifocal visual-evoked potentials in multiple sclerosis risk assessment.

De Santiago L, Ortiz Del Castillo M, Blanco R, Barea R, Rodríguez-Ascariz J M, Miguel-Jiménez J M, Sánchez-Morla E M, Boquete L

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To study the value of using the signal-to-noise ratio (SNR) of multifocal visual-evoked potentials (mfVEPs) in assessment of subjects at risk of developing multiple sclerosis (MS).

METHODS

MfVEP signals were obtained from 15 patients with radiologically isolated syndrome (RIS), from 28 patients with clinically isolated syndrome (CIS), from 28 with clinically definite MS and from 24 control subjects. The CIS and MS groups were divided into two subgroups: those with eyes affected by optic neuritis (ON) and those without (non-ON). The mfVEPs' SNR was obtained for both the whole visual field and at various eccentric rings. The area under the curve (AUC) was calculated by comparing the control subjects' mfVEP SNR values with those of the RIS, CIS and MS groups.

RESULTS

In whole visual field analysis, risk of developing MS increased as SNR decreased (SNRCONTROL=0.70, SNRRIS=0.62, SNRCIS-nonON=0.54, SNRCIS-ON=0.40, SNRMS-nonON=0.52, SNRMS-ON=0.40). Ring 5 (9.8°-15° eccentricity) was most affected by the SNR decrease, as indicated by its higher AUC values (AUCFULL_EYE=0.81, AUCRING_5=0.89). A significant relationship (Spearman correlation, ρRING_5=0.61) between SNR values and disability severity on the Expanded Disability Status Scale (EDSS) was observed in clinically definite MS patients.

CONCLUSION

A new method based on analysis of the SNR of mfVEP signal amplitude improves assessment of patients at risk of developing MS.

SIGNIFICANCE: Improved mfVEP assessment of MS-risk patients was achieved by using SNR values at 9.8°-15° eccentricity of the visual field.

Для цитирования: De Santiago L, Ortiz Del Castillo M, Blanco R, Barea R, Rodríguez-Ascariz J M, Miguel-Jiménez J M, Sánchez-Morla E M, Boquete L. A signal-to-noise-ratio-based analysis of multifocal visual-evoked potentials in multiple sclerosis risk assessment.. Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology. 2015. DOI: 10.1016/j.clinph.2015.09.129.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.