Hemostasis changes during veno-venous extracorporeal membrane oxygenation for respiratory support in adults.
Аннотация
BACKGROUND
We investigated the coagulation system in patients during extracorporeal membrane oxygenation (ECMO) initiated for respiratory failure and the influence of the ECMO circuit on coagulation tests; we compared different coagulation tests for monitoring unfractionated heparin (UH) therapy; we investigated whether or not coagulation parameters were predictive of bleeding during ECMO.
METHODS
Pilot study on twelve consecutive adult patients admitted at our general ICU for acute respiratory failure and placed on ECMO from November 2011 to October 2012. Coagulation tests were performed before ECMO start and daily, including day of circuit change and day of circuit removal. UH was monitored with activated partial thromboplastin time (APTT) ratio, at a therapeutic range of 1.5-2.0.
RESULTS
We observed no effect of ECMO circuit on coagulation parameters measured pre- and postlung, but platelet count decreased significantly over time (-82x10(3)/mmc, 95%CI 40-123). APTT showed a correlation with antifactor Xa activity, whereas other global coagulation tests such as activated clotting time, thromboelastography and endogenous thrombin potential did not. Major bleeding occurred in three patients but no difference in any coagulation parameter was observed between them and those who did not bleed.
CONCLUSIONS
This pilot study shows that ECMO initiated for respiratory support in adults does not change coagulation parameters. Over time a statistically significant reduction of platelet count was observed, possibly due to consumption within the circuit, consumption microangiopathy or the underlying patients' diseases. Although APTT was appropriate to monitor UH, major bleedings occurred and a lower therapeutic range may be advisable.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.