BACKGROUND

Evidence suggests differences in ventilation efficiency and respiratory mechanics between early COVID-19 pneumonia and classical acute respiratory distress syndrome (ARDS), as measured by established ventilatory indexes, such as the ventilatory ratio (VR; a surrogate of the pulmonary dead-space fraction) or mechanical power (MP; affected, e.g., by changes in lung-thorax compliance).

OBJECTIVES

The aim of this study was to evaluate VR and MP in the late stages of the disease when patients are ready to be liberated from the ventilator after recovering from COVID-19 pneumonia compared to respiratory failures of other etiologies.

DESIGN

A retrospective observational cohort study of 249 prolonged mechanically ventilated, tracheotomized patients with and without COVID-19-related respiratory failure.

METHODS

We analyzed each group's VR and MP distributions and trajectories [repeated-measures analysis of variance (ANOVA)] during weaning. Secondary outcomes included weaning failure rates between groups and the ability of VR and MP to predict weaning outcomes (using logistic regression models).

RESULTS

The analysis compared 53 COVID-19 cases with a heterogeneous group of 196 non-COVID-19 subjects. VR and MP decreased across both groups during weaning. COVID-19 patients demonstrated higher values for both indexes throughout weaning: median VR 1.54 versus 1.27 (p < 0.01) and MP 26.0 versus 21.3 Joule/min (p < 0.01) at the start of weaning, and median VR 1.38 versus 1.24 (p < 0.01) and MP 24.2 versus 20.1 Joule/min (p < 0.01) at weaning completion. According to the multivariable analysis, VR was not independently associated with weaning outcomes, and the ability of MP to predict weaning failure or success varied with lung-thorax compliance, with COVID-19 patients demonstrating consistently higher dynamic compliance along with significantly fewer weaning failures (9% versus 30%, p < 0.01).

CONCLUSION

COVID-19 patients differed considerably in ventilation efficiency and respiratory mechanics among prolonged ventilated individuals, demonstrating significantly higher VRs and MP. The differences in MP were linked with higher lung-thorax compliance in COVID-19 patients, possibly contributing to the lower rate of weaning failures observed.

Для цитирования: Ghiani Alessandro, Tsitouras Konstantinos, Paderewska Joanna, Kahnert Kathrin, Walcher Swenja, Gernhold Lukas, Neurohr Claus, Kneidinger Nikolaus. Ventilatory ratio and mechanical power in prolonged mechanically ventilated COVID-19 patients versus respiratory failures of other etiologies.. Therapeutic advances in respiratory disease. 2023. DOI: 10.1177/17534666231155744.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.