MedElevator Войти в исследования
← Поиск публикаций

DOI 10.14202/vetworld.2019.740-747

Медицинская библиотека · Veterinary world · 2019

Echocardiographic study of healthy Indian Spitz dogs with normal reference ranges for the breed.

Bodh Deepti, Hoque Mozammel, Saxena Abhishek Chandra

СтатьяПеревод пока не подготовлен

Аннотация

AIM: The present study was aimed to determine the normal reference values of M-mode echocardiographic measurements in healthy Indian Spitz dogs and evaluate the influence of gender and body weight on these measurements.

MATERIALS AND

METHODS

M-mode echocardiography was performed in twenty-four clinically healthy conscious Indian Spitz dogs, aged 3-5 years and weighing 7-18 kg. Measurements were made from the right parasternal long axis left ventricular outflow tract view of the heart. The parameters recorded were: Left ventricular internal dimension, interventricular septal thickness and left ventricular posterior wall thickness during diastole and systole, left atrial diameter, aortic root diameter, left ventricular systolic functional parameters, and indices and mitral valve parameters.

RESULTS

M-mode echocardiographic measurements in healthy Indian Spitz dogs were standardized. Gender had no influence on echocardiographic measurements except mitral valve excursion amplitude and time interval between onset and end of mitral valve closure, which were significantly (p<0.05) higher in females than males. Left ventricular internal dimension at end-diastole, left ventricular internal dimension at end-systole, left ventricular posterior wall dimension at end-systole, end-diastolic volume, end-systolic volume, stroke volume, cardiac output, left ventricular ejection time, and mitral valve excursion amplitude correlated significantly (p<0.05) with body weight in Indian Spitz dogs.

CONCLUSION

Data obtained in the present study can be used as breed-specific reference values for cardiac disease diagnosis as well as for future studies in Indian Spitz dogs.

Для цитирования: Bodh Deepti, Hoque Mozammel, Saxena Abhishek Chandra. Echocardiographic study of healthy Indian Spitz dogs with normal reference ranges for the breed.. Veterinary world. 2019. DOI: 10.14202/vetworld.2019.740-747.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.