Critical care explorations · 2022
Physiologic Effects of the Awake Prone Position Combined With High-Flow Nasal Oxygen on Gas Exchange and Work of Breathing in Patients With Severe COVID-19 Pneumonia: A Randomized Crossover Trial.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lehingue Samuel, Allardet-Servent Jérôme, Ferdani Anne, Hraeich Sami, Forel Jean-Marie, Arnal Jean-Michel, Prud'homme Eloi, Penaranda Guillaume, Bourenne Jeremy, Monnet Olivier, Gainnier Marc, Cantais Emmanuel
Аннотация
UNLABELLED: To determine the effect of the awake prone position (APP) on gas exchange and the work of breathing in spontaneously breathing patients with COVID-19-associated acute hypoxemic respiratory failure (AHRF) supported by high-flow nasal oxygen.
DESIGN: Prospective randomized physiologic crossover multicenter trial.
SETTINGS: Four ICUs in Marseille, France.
PATIENTS: Seventeen patients with laboratory-confirmed COVID-19 pneumonia and Pao2/Fio2 less than or equal to 300 mm Hg while treated with high-flow nasal cannula oxygen therapy.
INTERVENTIONS: Periods of APP and semirecumbent position (SRP) were randomly applied for 2 hours and separated by a 2-hour washout period.
MEASUREMENTS AND MAIN RESULTS: Arterial blood gases, end-tidal CO2. and esophageal pressure were recorded prior to and at the end of each period. Inspiratory muscle effort was assessed by measuring the esophageal pressure swing (∆PES) and the simplified esophageal pressure-time product (sPTPES). The other endpoints included physiologic dead space to tidal volume ratio (VD/VT) and the transpulmonary pressure swing. The APP increased the Pao2/Fio2 from 84 Torr (61-137 Torr) to 208 Torr (114-226 Torr) (p = 0.0007) and decreased both the VD/VT and the respiratory rate from 0.54 (0.47-0.57) to 0.49 (0.45-0.53) (p = 0.012) and from 26 breaths/min (21-30 breaths/min) to 21 breaths/min (19-22 breaths/min), respectively (p = 0.002). These variables remained unchanged during the SRP. The ∆PES and sPTPES per breath were unaffected by the position. However, the APP reduced the sPTPES per minute from 225 cm H2O.s.m-1 (176-332 cm H2O.s.m-1) to 174 cm H2O.s.m-1 (161-254 cm H2O.s.m-1) (p = 0.049).
CONCLUSIONS: In spontaneously breathing patients with COVID-19-associated AHRF supported by high-flow nasal oxygen, the APP improves oxygenation and reduces the physiologic dead space, respiratory rate, and work of breathing per minute.
DESIGN: Prospective randomized physiologic crossover multicenter trial.
SETTINGS: Four ICUs in Marseille, France.
PATIENTS: Seventeen patients with laboratory-confirmed COVID-19 pneumonia and Pao2/Fio2 less than or equal to 300 mm Hg while treated with high-flow nasal cannula oxygen therapy.
INTERVENTIONS: Periods of APP and semirecumbent position (SRP) were randomly applied for 2 hours and separated by a 2-hour washout period.
MEASUREMENTS AND MAIN RESULTS: Arterial blood gases, end-tidal CO2. and esophageal pressure were recorded prior to and at the end of each period. Inspiratory muscle effort was assessed by measuring the esophageal pressure swing (∆PES) and the simplified esophageal pressure-time product (sPTPES). The other endpoints included physiologic dead space to tidal volume ratio (VD/VT) and the transpulmonary pressure swing. The APP increased the Pao2/Fio2 from 84 Torr (61-137 Torr) to 208 Torr (114-226 Torr) (p = 0.0007) and decreased both the VD/VT and the respiratory rate from 0.54 (0.47-0.57) to 0.49 (0.45-0.53) (p = 0.012) and from 26 breaths/min (21-30 breaths/min) to 21 breaths/min (19-22 breaths/min), respectively (p = 0.002). These variables remained unchanged during the SRP. The ∆PES and sPTPES per breath were unaffected by the position. However, the APP reduced the sPTPES per minute from 225 cm H2O.s.m-1 (176-332 cm H2O.s.m-1) to 174 cm H2O.s.m-1 (161-254 cm H2O.s.m-1) (p = 0.049).
CONCLUSIONS: In spontaneously breathing patients with COVID-19-associated AHRF supported by high-flow nasal oxygen, the APP improves oxygenation and reduces the physiologic dead space, respiratory rate, and work of breathing per minute.