MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.pupt.2013.01.005

Медицинская библиотека · Pulmonary pharmacology & therapeutics · 2013

Multidetector-row computed tomography assessment of adding budesonide/formoterol to tiotropium in patients with chronic obstructive pulmonary disease.

Yasui Hideki, Inui Naoki, Furuhashi Kazuki, Nakamura Yutaro, Uto Tomohiro, Sato Jun, Yasuda Kazumasa, Takehara Yasuo, Suda Takafumi, Chida Kingo

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In patients with chronic obstructive pulmonary disease (COPD), multidetector-row computed tomography (MDCT) showed that tiotropium dilated the inner diameters in airways from the third to the sixth generation of the bronchi. Here we aimed to evaluate the morphological effect by adding a budesonide/formoterol combination to tiotropium in COPD patients using three-dimensional MDCT.

METHODS

Pulmonary function tests, St. George's Respiratory Questionnaire (SGRQ) and MDCT imaging studies were performed at the beginning and after budesonide/formoterol combination treatment for 12 weeks in 14 patients with COPD.

RESULTS

The median age was 73.5 years and the mean forced expiratory volume in 1 s (FEV1) as a percentage of the predicted value was 57.2 ± 18.3%. The luminal area in the fifth generation bronchi and the emphysema volume/CT-derived total lung volume were significantly correlated with FEV1 at baseline (r = 0.682, p < 0.02 and r = -0.868, p < 0.001, respectively). The average luminal area and wall area percentage in the third, fourth and fifth generations were correlated with the SGRQ total score. Budesonide/formoterol induced insignificant pulmonary function changes and significant symptoms improvement. CT images showed an increased inner luminal area and decreased wall area after budesonide/formoterol treatment. Average luminal area was significantly increased from 24.3 ± 9.7 to 26.0 ± 9.9 mm(2) in the third generation, 13.0 ± 6.5 to 14.7 ± 7.3 mm(2) in the fourth generation, 8.0 ± 4.8 to 9.4 ± 4.9 mm(2) in the fifth generation and 5.6 ± 2.7 to 6.7 ± 3.6 mm(2) in the sixth generation (p < 0.01). The average increase of the third generation luminal area was correlated with the FEV1 increase (r = 0.632, p < 0.03). The wall area percentage significantly decreased from 51.5 ± 9.2 to 49.1 ± 9.7 in the third generation, 56.1 ± 9.7 to 53.0 ± 11.1 in the fourth generation, and 62.3 ± 9.9 to 57.6 ± 9.8 in the fifth generation (p < 0.05). Emphysema volume/CT-derived total lung volume was unchanged with treatment.

CONCLUSION

MDCT demonstrated budesonide/formoterol induced bronchodilation in the non-small airway. CT imaging can evaluate drug therapeutic effect and may provide additional insights into pharmacotherapy for COPD.

Для цитирования: Yasui Hideki, Inui Naoki, Furuhashi Kazuki, Nakamura Yutaro, Uto Tomohiro, Sato Jun, Yasuda Kazumasa, Takehara Yasuo, Suda Takafumi, Chida Kingo. Multidetector-row computed tomography assessment of adding budesonide/formoterol to tiotropium in patients with chronic obstructive pulmonary disease.. Pulmonary pharmacology & therapeutics. 2013. DOI: 10.1016/j.pupt.2013.01.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.