MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.gie.2013.07.061

Медицинская библиотека · Gastrointestinal endoscopy · 2013

Colon capsule endoscopy is feasible to perform after incomplete colonoscopy and guides further workup in clinical practice.

Triantafyllou Konstantinos, Viazis Nikos, Tsibouris Panagiotis, Zacharakis Georgios, Kalantzis Chryssostomos, Karamanolis Demetrios G, Ladas Spiros D

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Colon capsule endoscopy (CCE) could be an option to examine the colon after incomplete colonoscopy.

OBJECTIVE

To investigate the extent that CCE complements incomplete colonoscopy and guides further workup.

DESIGN

Prospective, follow-up study.

SETTING

Three tertiary-care centers.

PATIENTS: Consecutive outpatients after colonoscopy failure; 1-year study period.

INTERVENTION: Patients underwent CCE either immediately after colonoscopy or were rescheduled. Further investigations were guided by the results of CCE. Patients were followed as long as 2 years.

RESULTS

We studied 75 outpatients; 39 had a screening colonoscopy. One third of the patients underwent CCE immediately after colonoscopy. Overall, CCE reached or went beyond the colon segment at which colonoscopy stopped in 68 patients (91%). CCE technically complemented difficult colonoscopy independently of whether same-day CCE was performed (24 [96%]) or was not performed (44 [88%]). CCE detected additional significant findings in 36% of the same-day CCE cases and in 48% of the rescheduled ones. Two patients in the same-day group and 13 in the rescheduled CCE group underwent further colon examination that revealed additional significant findings in 3 of them. Ten percent of the patients reported mild adverse events (AE). If needed, 63 participants (84%) were willing to repeat CCE. Follow-up has not identified symptomatic missed colon cancers.

LIMITATIONS: Selected patient population, first-generation colon capsule, old preparation scheme.

CONCLUSION

CCE performed immediately or at a scheduled date after colonoscopy failure is feasible and safe. CCE after incomplete colonoscopy appears to yield significant findings, guide further workup, and has high patient acceptance.

Для цитирования: Triantafyllou Konstantinos, Viazis Nikos, Tsibouris Panagiotis, Zacharakis Georgios, Kalantzis Chryssostomos, Karamanolis Demetrios G, Ladas Spiros D. Colon capsule endoscopy is feasible to perform after incomplete colonoscopy and guides further workup in clinical practice.. Gastrointestinal endoscopy. 2013. DOI: 10.1016/j.gie.2013.07.061.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.