MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20191217-01

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2020

Three-Step Treatment of Keratoconus and Post-LASIK Ectasia: Implantation of ICRS, Corneal Cross-linking, and Implantation of Toric Posterior Chamber Phakic IOLs.

He Chunchun, Joergensen Joern S, Knorz Michael C, McKay Keith N, Zhang Fengju

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate vision and corneal surface regularity after each step of a three-step surgical treatment of keratoconus and post-laser in situ keratomileusis (LASIK) ectasia (implantation of intracorneal ring segments [ICRS], corneal cross-linking [CXL], and implantation of toric intraocular contact lenses [ICLs]).

METHODS

Thirty-one eyes of 24 patients with moderate to severe keratoconus and post-LASIK ectasia (stages II and III of Amsler-Krumeich classification) were included. All eyes underwent all three steps. The time interval between ICRS implantation and CXL was 4 to 6 weeks, and ICL implantation was performed 6 to 8 months after CXL. Visual acuity, refraction, and corneal topometric indices were evaluated with the Pentacam system (index of surface variance [ISV], index of vertical asymmetry [IVA], keratoconus index [KI], central keratoconus index [CKI], index of height asymmetry [IHA], index of height decentration [IHD], and corneal wavefront parameters [eg, higher order aberrations, spherical aberration, and coma]).

RESULTS

Decimal uncorrected distance visual acuity (UDVA) improved from 0.13 ± 0.17 preoperatively to 0.69 ± 0.18 at 1 year, whereas corrected distance visual acuity (CDVA) improved from 0.56 ± 0.24 to 0.80 ± 0.18, respectively. The topometric indices ISV, IVA, KI, and IHD also improved significantly, whereas CKI and IHA showed no significant improvement. Higher order aberrations, spherical aberration, and coma improved significantly compared to baseline.

CONCLUSIONS

The combined use of ICRS, CXL, and ICL implantation significantly improves visual acuity, higher order aberrations, and corneal shape in moderate and severe keratoconus and post-LASIK ectasia. [J Refract Surg. 2020;36(2):104-109.].

Для цитирования: He Chunchun, Joergensen Joern S, Knorz Michael C, McKay Keith N, Zhang Fengju. Three-Step Treatment of Keratoconus and Post-LASIK Ectasia: Implantation of ICRS, Corneal Cross-linking, and Implantation of Toric Posterior Chamber Phakic IOLs.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2020. DOI: 10.3928/1081597x-20191217-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.