MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ojo.ojo_43_2018

Медицинская библиотека · Oman journal of ophthalmology · 2019

Contact lens fitting after corneal collagen cross-linking.

Mandathara Preeji Suderman, Kalaiselvan Parthasarathi, Rathi Varsha M, Murthy Somasheila I, Taneja Mukesh, Sangwan Virender S

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Contact lenses (CLs) remain the mainstay in improving vision in patients having keratoconus. With corneal collagen cross-linking (CXL) performed worldwide, whether the same CLs can be used or needs replacement needed to be assessed and considered.

AIMS: The aim of this study was to evaluate the changes in CL fitting following CXL.

SETTINGS AND

DESIGN

This is a retrospective study conducted at a tertiary center.

SUBJECTS AND

METHODS

We analyzed the medical records of patients who underwent CXL and used CL. Data collected included demographics, pre- and post-CXL refraction, corneal topography, anterior-segment examination, and CL [rigid gas permeable(RGP)] fitting details and duration between CXL and RGP fitting.

STATISTICAL ANALYSIS: Descriptive analysis and paired t-test were used to compare the pre- and post-CXL data on refraction, visual acuity, and CL parameters. The statistical significance was kept at P < 0.05.

RESULTS

Thirty-four eyes (keratoconus = 32, pellucid marginal degeneration = 1, and post-LASIK ectasia = 1) of 27 patients who used CL before and after undergoing CXL were analyzed. Mean duration between CXL and RGP lens use was 2.53 months. Mean sphere and cylinder post-CXL was -4.11 ± 4.32 D and -3.54 ± 2.51 D, respectively. A mean change of 0.75 ± 3.72 D sphere and 0.71 ± 3.39 D cylinder was noted post-CXL. The post-CXL best spectacle-corrected visual acuity (CVA) was 0.52 ± 0.36 and with RGP lens it was 0.09 ± 0.18. There was no significant difference in pre- and post-CXL RGP lens CVA (0.07 ± 0.09 and 0.09 ± 0.18, respectively; P = 0.556). Pre-CXL, 3-point-touch fitting was in 24 eyes (70.59%) and central fluorescein pooling was in 10 eyes (29.41%). Post-CXL, 30 eyes (88.24%) had 3-point-touch and central fluorescein pooling was found in four eyes (11.76%). One patient had CL intolerance after CXL. Of the 32 keratoconus eyes, 62.5% (n = 20 eyes) were prescribed new lenses; 37.5% (n = 12 eyes) continued using own lenses.

CONCLUSIONS

There was no significant difference in refraction, topography indices, and RGP lens parameters pre- and post-CXL. However, changes in RGP lens fitting characteristics suggest a possible change in shape or apex location of the cornea after CXL. RGP lenses remain the best option to improve visual acuity after CXL in corneal ectasia.

Для цитирования: Mandathara Preeji Suderman, Kalaiselvan Parthasarathi, Rathi Varsha M, Murthy Somasheila I, Taneja Mukesh, Sangwan Virender S. Contact lens fitting after corneal collagen cross-linking.. Oman journal of ophthalmology. 2019. DOI: 10.4103/ojo.ojo_43_2018.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.