MedElevator Войти в исследования
← Поиск публикаций

DOI 10.18502/jovr.v14i4.5443

Медицинская библиотека · Journal of ophthalmic & vision research · 2019

Changes in Corneal Asphericity after MyoRing Implantation in Moderate and Severe Keratoconus.

Khorrami-Nejad Masoud, Aghili Ozra, Hashemian Hesam, Aghazadeh-Amiri Mohamad, Karimi Farshid

СтатьяОбзорПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the effect of MyoRing implantation on corneal asphericity in moderate and severe keratoconus (KCN).

METHODS

This cross-sectional observational study comprised 32 eyes of 28 patients with KCN, who had femtosecond-assisted MyoRing corneal implantation. The primary outcome measures were preoperative and six-month postoperative corneal asphericity in 6-, 7-, 8-, 9-, and 10-mm optical zones in the superior, inferior, nasal, temporal, and central areas. The secondary outcome measures included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, thinnest location value, and keratometry readings.

RESULTS

A significant improvement in the UDVA and CDVA was observed six months after the surgery (P < 0.001) with a significant reduction in the spherical (4.67 diopters (D)) and cylindrical (2.19 D) refractive errors. A significant reduction in the corneal asphericity in all the optical zones and in the superior, inferior, nasal, temporal, and central areas was noted (P < 0.001). The mean thickness at the thinnest location of the cornea decreased from 437.15 ± 30.69 to 422.81 ± 36.91 μm. A significant corneal flattening was seen. The K1, K2, and Km changes were 5.32 D, 7 D, and 6.17 D, respectively (P < 0.001).

CONCLUSION

MyoRing implantation is effective for improving corneal asphericity in patients with KCN. It allows successful corneal remodeling and provides a significant improvement in UDVA, CDVA, and refractive errors.

Для цитирования: Khorrami-Nejad Masoud, Aghili Ozra, Hashemian Hesam, Aghazadeh-Amiri Mohamad, Karimi Farshid. Changes in Corneal Asphericity after MyoRing Implantation in Moderate and Severe Keratoconus.. Journal of ophthalmic & vision research. 2019. DOI: 10.18502/jovr.v14i4.5443.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.