MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjopen-2019-031313

Медицинская библиотека · BMJ open · 2019

Keratoconus detection using deep learning of colour-coded maps with anterior segment optical coherence tomography: a diagnostic accuracy study.

Kamiya Kazutaka, Ayatsuka Yuji, Kato Yudai, Fujimura Fusako, Takahashi Masahide, Shoji Nobuyuki, Mori Yosai, Miyata Kazunori

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the diagnostic accuracy of keratoconus using deep learning of the colour-coded maps measured with the swept-source anterior segment optical coherence tomography (AS-OCT).

DESIGN

A diagnostic accuracy study.

SETTING

A single-centre study.

PARTICIPANTS

A total of 304 keratoconic eyes (grade 1 (108 eyes), 2 (75 eyes), 3 (42 eyes) and 4 (79 eyes)) according to the Amsler-Krumeich classification, and 239 age-matched healthy eyes.

MAIN OUTCOME MEASURES: The diagnostic accuracy of keratoconus using deep learning of six colour-coded maps (anterior elevation, anterior curvature, posterior elevation, posterior curvature, total refractive power and pachymetry map).

RESULTS

Deep learning of the arithmetical mean output data of these six maps showed an accuracy of 0.991 in discriminating between normal and keratoconic eyes. For single map analysis, posterior elevation map (0.993) showed the highest accuracy, followed by posterior curvature map (0.991), anterior elevation map (0.983), corneal pachymetry map (0.982), total refractive power map (0.978) and anterior curvature map (0.976), in discriminating between normal and keratoconic eyes. This deep learning also showed an accuracy of 0.874 in classifying the stage of the disease. Posterior curvature map (0.869) showed the highest accuracy, followed by corneal pachymetry map (0.845), anterior curvature map (0.836), total refractive power map (0.836), posterior elevation map (0.829) and anterior elevation map (0.820), in classifying the stage.

CONCLUSIONS

Deep learning using the colour-coded maps obtained by the AS-OCT effectively discriminates keratoconus from normal corneas, and furthermore classifies the grade of the disease. It is suggested that this will become an aid for improving the diagnostic accuracy of keratoconus in daily practice.

CLINICAL TRIAL REGISTRATION NUMBER: 000034587.

Для цитирования: Kamiya Kazutaka, Ayatsuka Yuji, Kato Yudai, Fujimura Fusako, Takahashi Masahide, Shoji Nobuyuki, Mori Yosai, Miyata Kazunori. Keratoconus detection using deep learning of colour-coded maps with anterior segment optical coherence tomography: a diagnostic accuracy study.. BMJ open. 2019. DOI: 10.1136/bmjopen-2019-031313.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.