MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2019.03.017

Медицинская библиотека · Journal of cataract and refractive surgery · 2019

Comparison of eye-rubbing effect in keratoconic eyes and healthy eyes using Scheimpflug analysis and a dynamic bidirectional applanation device.

Henriquez Maria A, Cerrate Michelle, Hadid Marta G, Cañola-Ramirez Laura A, Hafezi Farhad, Izquierdo Luis

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the effect of eye rubbing on Scheimpflug imaging parameters and corneal biomechanics in eyes with keratoconus and healthy eyes.

SETTING

Oftalmosalud Instituto de Ojos, Lima, Peru.

DESIGN

Prospective cohort study.

METHODS

The study included healthy and keratoconus patients who attended the institution between January 2017 and July 2017. Eye rubbing was performed for 1 minute followed by a 5-second break, followed by further rubbing for 1 minute. Baseline tests were performed before rubbing; post-rubbing tests were performed immediately after (0 minutes), and then again at 7 minutes and 14 minutes. Parameters related to anterior and posterior curvature and elevation, pachymetry, and corneal biomechanics obtained from tomography with a rotating Scheimpflug camera (Pentacam HR) and a dynamic bidirectional applanation device (Ocular Response Analyzer) were measured and compared between healthy and keratoconic eyes.

RESULTS

The study included 30 healthy eyes and 31 keratoconic eyes. In the healthy group, the immediate mean changes in steeper anterior keratometry, posterior astigmatism, anterior chamber volume (ACV), flattest posterior keratometry, and Goldmann-correlated intraocular pressure (IOPg) after eye rubbing were 0.07 diopters (D) ± 0.15 (SD), -0.01 ± 0.08 D, 0.03 ± 7.06 mm3, -0.001 ± 0.04 mm, and -1.21 ± 1.99 mm Hg, respectively, whereas the mean changes in the keratoconus group were -0.03 ± 0.32 D, 0.14 ± 0.50 D, -5.09 ± 8.45 mm3, 0.03 ± 0.06 mm, and -1.61 ± 1.41 mm Hg, respectively. There were statistically significant differences between the preoperative and postoperative eye-rubbing values of posterior astigmatism, ACV, and IOPg in the keratoconus group (P = .03, P = .0003, and P = .001, respectively) but not in the healthy group (P = .65, P = .85, and P = .23, respectively).

CONCLUSIONS

Unlike the healthy eyes group, the keratoconus group experienced significant changes in ACV, IOP, and corneal posterior astigmatism after eye rubbing.

Для цитирования: Henriquez Maria A, Cerrate Michelle, Hadid Marta G, Cañola-Ramirez Laura A, Hafezi Farhad, Izquierdo Luis. Comparison of eye-rubbing effect in keratoconic eyes and healthy eyes using Scheimpflug analysis and a dynamic bidirectional applanation device.. Journal of cataract and refractive surgery. 2019. DOI: 10.1016/j.jcrs.2019.03.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.