Discrepancies between estimated and geometrically derived mechanical power in invasively ventilated patients - insights from a randomized clinical trial.

Serafini Simon Corrado, Geerts Jan Willem H J, Neto Ary Serpa, List Stephanie S, von Düring Stephan, Tschernko Edda, Bühler Philipp, Mazzinari Guido, Paulus Frederique, Schultz Marcus J, Buiteman-Kruizinga Laura A, INTELLiPOWER collaborative investigators

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Mechanical power (MP) quantifies the energy transferred from the ventilator to the respiratory system and is increasingly linked to outcomes in invasively ventilated critically ill patients. Limiting MP may support lung-protective ventilation by integrating key determinants of ventilator-induced lung injury. While geometric MP, derived from pressure-volume loops, is considered the reference standard, it is not readily available at the bedside. Therefore, simplified equations are commonly used, although their agreement remains uncertain. This study evaluates the agreement of previously proposed equations to estimate inspiratory MP compared with a geometric reference.

RESULTS

494 paired values of geometric and estimated MP were collected, in 38 passively ventilated patients during closed-loop ventilation and during conventional ventilation. The median geometric MP was 17.0 [12.3-21.5] J/min. Correlation between geometric and estimated MP ranged from strong to very strong. Agreement between geometric and estimated MP was good, though bias and limits of agreement varied across the different equations. ROC analysis showed excellent discrimination for most equations across all tested cutoffs, with discrimination gradually declining at higher MP levels.

CONCLUSION

In passively ventilated critically ill patients, estimated MP showed strong to very strong correlations with the geometric reference. ROC analysis confirmed excellent discrimination, but Bland-Altman analysis revealed considerable variability, suggesting potential limitations in using these equations interchangeably in clinical or research settings.

STUDY REGISTRATION: INTELLiPOWER was registered at clinicaltrials.gov (study identifier NCT04827927).

Для цитирования: Serafini Simon Corrado, Geerts Jan Willem H J, Neto Ary Serpa, List Stephanie S, von Düring Stephan, Tschernko Edda, Bühler Philipp, Mazzinari Guido, Paulus Frederique, Schultz Marcus J, Buiteman-Kruizinga Laura A, INTELLiPOWER collaborative investigators. Discrepancies between estimated and geometrically derived mechanical power in invasively ventilated patients - insights from a randomized clinical trial.. Intensive care medicine experimental. 2026. DOI: 10.1186/s40635-026-00956-8.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.