Impact of ultrasound and optical biometry on refractive outcomes of cataract surgery after penetrating keratoplasty in keratoconus.
Аннотация
AIM: To analyse the impact of ultrasound and optical intraocular lens (IOL) calculation methods on refractive outcomes of cataract phacoemulsification performed after penetrating keratoplasty (PK) in keratoconus.
METHODS
Phacoemulsification cataract surgery was performed on 42 eyes of 34 patients with keratoconus who had previously undergone PK. The IOL power was determined by using both standard and corneal topography-derived keratometry using the SRK/T formula. We used two independent methods-ultrasound biometry (UB) and interferometry [optical biometry (OB)] for IOL calculation. The analysed data from medical records included demographics, medical history, best corrected visual acuity (BCVA) on Snellen charts, technique of IOL calculation and calculation formula and its impact on final refractive result.
RESULTS
BCVA ranged from 0.01 to 0.4 (mean 0.09±0.19) before surgery and ranged from 0.2 to 0.7 (mean 0.38±0.14) at 1mo and from 0.2 to 1.0 (mean 0.56±0.16) (P<0.05) at 3mo, postoperatively. The refractive aim differed significantly from the refractive outcome in both the UB and OB groups (P<0.05). There was no statistically significant difference in the accuracy of the two biometry methods.
CONCLUSION
The refractive aim in keratoconus eyes post-PK is not achieved with either ultrasound or OB.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.