Limited evidence on the use of fibrin clot as an adjunct to meniscal repair with sutures: A systematic review.

de Azevedo Laura Amaral Coelho, de Novaes Rayanne Carneiro Torres, Del Campo Gabriela de Paula Leite Rocha Alcântara, Junqueira Maria Fernanda Pereira, de Oliveira Diego Escudeiro, Jorge Pedro Baches

СтатьяОбзорПеревод пока не подготовлен

Аннотация

PURPOSE: Meniscal tears are common knee injuries that often require surgical repair due to pain and mechanical symptoms. Limited vascularisation in specific meniscal regions hinders healing, encouraging the use of fibrin clots as a biological augmentation strategy. This study aims to critically evaluate the available evidence on the use of fibrin clot as a biological adjunct in meniscal repair with sutures and its potential impact on healing outcomes.

METHODS

A systematic review was conducted following the PRISMA guidelines, encompassing the PubMed, Embase and Scopus databases up to April 2025. Studies investigating meniscal repair augmented with a fibrin clot were included in the analysis. Data extracted included study design, type of meniscal lesion, surgical technique, clot preparation and failure rates.

RESULTS

Eleven studies were included, comprising both retrospective case series and limited comparative studies. Most studies involved small sample sizes and heterogeneous populations, characterised by diverse meniscal tear patterns, surgical techniques and clot sources. Reported healing rates ranged from 43% to above 90%, but outcome definitions were inconsistent. A critical risk of bias was identified in most of the studies.

CONCLUSIONS

The current evidence on the use of fibrin clot as an adjunct to meniscal repair is limited and inconsistent. Although some studies suggest potential benefits, the overall quality of evidence is low. Further high-quality randomised controlled trials are needed to determine whether fibrin clot improves meniscal healing outcomes.

LEVEL OF EVIDENCE: Level IV, systematic review.

CLINICAL TRAIL REGISTRATION: This systematic review was registered in PROSPERO (registration number: CRD42024614021).

Для цитирования: de Azevedo Laura Amaral Coelho, de Novaes Rayanne Carneiro Torres, Del Campo Gabriela de Paula Leite Rocha Alcântara, Junqueira Maria Fernanda Pereira, de Oliveira Diego Escudeiro, Jorge Pedro Baches. Limited evidence on the use of fibrin clot as an adjunct to meniscal repair with sutures: A systematic review.. Journal of experimental orthopaedics. 2025. DOI: 10.1002/jeo2.70503.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.