DOI 10.1007/s10549-020-05881-2

Медицинская библиотека · Breast cancer research and treatment · 2020

Clinical performance of contrast-enhanced spectral mammography in pre-surgical evaluation of breast malignant lesions in dense breasts: a single center study.

Bozzini Anna, Nicosia Luca, Pruneri Giancarlo, Maisonneuve Patrick, Meneghetti Lorenza, Renne Giuseppe, Vingiani Andrea, Cassano Enrico, Mastropasqua Mauro Giuseppe

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the efficacy of contrast-enhanced spectral mammography, with ultrasound, full field digital mammography and magnetic resonance imaging in detection and size estimation of histologically proven breast tumors.

METHODS

This open-label, single center, prospective study, included 160 dense breast women with at least one suspicious mammary lesion evaluated by ultrasound, full field digital mammography and magnetic resonance imaging in whom a mammary tumor was histologically proven after surgery performed at the European Institute of Oncology between January 2013 and December 2015. Following the complete diagnostic procedure, the patients were further investigated by contrast-enhanced spectral mammography prior to surgery.

RESULTS

Overall, the detection rate of malignant breast lesions (in situ and invasive) was 93.8% (165/176) for contrast-enhanced spectral mammography, 94.4% (168/178) for ultrasound, 85.5 (147/172) for full field digital mammography and 97.7% (173/177) for magnetic resonance imaging. Radiological measurements were concordant with the post-surgical pathological measurements of the invasive tumor (i.e., within 5 mm) in: 64.6% for contrast-enhanced spectral mammography, 62.0% for ultrasound, 45.2% for full field digital mammography (p < 0.0001) and 69.9% for magnetic resonance imaging (p = 0.28); underestimated in: 17.4% for contrast-enhanced spectral mammography, 19.6% for ultrasound, 24.2% for full field digital mammography (p = 0.03) and 6.7% for magnetic resonance imaging (p = 0.0005); and overestimated in: 16.2% for contrast-enhanced spectral mammography, 16.6% for ultrasound, 16.6% for full field digital mammography and 22.7% for magnetic resonance imaging (p = 0.02).

CONCLUSIONS

Our data suggest that contrast-enhanced spectral mammography improves on full field digital mammography and is comparable to ultrasound and magnetic resonance imaging in terms of detection sensitivity and size estimation of malignant lesions in dense breasts.

Для цитирования: Bozzini Anna, Nicosia Luca, Pruneri Giancarlo, Maisonneuve Patrick, Meneghetti Lorenza, Renne Giuseppe, Vingiani Andrea, Cassano Enrico, Mastropasqua Mauro Giuseppe. Clinical performance of contrast-enhanced spectral mammography in pre-surgical evaluation of breast malignant lesions in dense breasts: a single center study.. Breast cancer research and treatment. 2020. DOI: 10.1007/s10549-020-05881-2.