MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/cclm-2018-0733

Медицинская библиотека · Clinical chemistry and laboratory medicine · 2019

The rational specimen for the quantitative detection of Epstein-Barr virus DNA load.

Kedi Wang, Dongjiang Xu, Zhi Lv, Yan Gao, Kun Jia, Jianrong Su

СтатьяПеревод в очереди

Аннотация

Background Epstein-Barr virus (EBV) DNA load monitoring in blood is essential for the diagnosis of EBV-associated diseases. However, the best-suited blood compartment for detection is still under discussion. The aim of this study was to evaluate the diagnostic value of EBV-DNA load in peripheral blood mononuclear cells (PBMC), plasma and whole blood (WB) samples. Methods A total of 156 patients, including 45 patients with infectious mononucleosis (IM), 57 patients with EBV-associated hemophagocytic lymphohistiocytosis (HLH) and 54 patients with post-transplant lymphoproliferative disorders (PTLD), were enrolled in this study. The EBV-DNA load in PBMC, plasma and WB samples were measured with real-time quantitative polymerase chain reaction (PCR). Results EBV-DNA load of patients with HLH showed no statistical difference in PBMC, plasma and WB samples, while patients with IM and PTLD showed a higher viral load in PBMC samples. The strongest correlation of EBV-DNA level was found between PBMC and WB samples among patients with IM, HLH and PTLD. The follow-up of EBV-DNA showed that the viral load became negative along with the recovery from the disease, while that in WB and PBMC would remain positive for a long time. Conclusions For the diagnosis and monitoring of EBV-DNA, the type of specimen should be chosen reasonably according to the disease. As for IM and HLH, plasma is recommended to quantify the EBV-DNA load, while PBMC and plasma are preferred in PTLD.

Для цитирования: Kedi Wang, Dongjiang Xu, Zhi Lv, Yan Gao, Kun Jia, Jianrong Su. The rational specimen for the quantitative detection of Epstein-Barr virus DNA load.. Clinical chemistry and laboratory medicine. 2019. DOI: 10.1515/cclm-2018-0733.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.