MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00192-020-04390-6

Медицинская библиотека · International urogynecology journal · 2020

Is the fixation of single incision TVT-S tape as good as that of transobturator tape? An ultrasound study of randomized trial results.

Serdinsek Tamara, Martan Alois, Svabik Kamil, But Igor, Kolek Petr, Masata Jaromir

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

TVT-Secur (TVT-S) was the first single-incision sling available on the market and was soon found to have less efficacy than mid-urethral slings. Our aim was to assess the position and tape descent following TVT-O and TVT-S H in a U procedure and, based on this evaluation, to find the possible reason for lower TVT-S surgery efficacy.

METHODS

We conducted an ultrasound study of a randomised trial with a 3-year follow-up that took place between 2007 and 2009 and included 197 women with urodynamic stress urinary incontinence. Of these, 67 were allocated to receive the TVT-O procedure, 64 to TVT-S in the H position, and 65 in the U position. Patients underwent a complete urogynaecological and ultrasound examination. The positions of the bladder neck and the tape after surgery were assessed and the data obtained compared between groups.

RESULTS

Our primary study showed a significantly higher rate of positive stress tests in the TVT-S groups compared to the TVT-O group. After surgery, there was no difference between the position of the tape at rest and at maximal Valsalva between the groups. In TVT-O patients, the mean length of the upper tape margin descent increased from 6 mm on the 1st day after surgery to 9 mm 3 months after surgery and remained stable afterwards. For TVT-S patients, there was a further increase of up to 15 mm in tape descent after 3 months.

CONCLUSIONS

Our results show that the lower efficacy of TVT-S might be due to inadequate fixation and increasing tape descent.

Для цитирования: Serdinsek Tamara, Martan Alois, Svabik Kamil, But Igor, Kolek Petr, Masata Jaromir. Is the fixation of single incision TVT-S tape as good as that of transobturator tape? An ultrasound study of randomized trial results.. International urogynecology journal. 2020. DOI: 10.1007/s00192-020-04390-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.