MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.05.2081

Медицинская библиотека · AJR. American journal of roentgenology · 2007

Efficacy of helical dynamic CT versus integrated PET/CT for detection of mediastinal nodal metastasis in non-small cell lung cancer.

Yi Chin A, Lee Kyung Soo, Kim Byung-Tae, Shim Sung Shine, Chung Myung Jin, Sung Yon Mi, Jeong Sun Young

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The purpose of our study was to compare the diagnostic efficacies of helical dynamic CT and integrated PET/CT for the prediction of mediastinal nodal metastasis in stage T1 non-small cell lung cancer (NSCLC).

MATERIALS AND

METHODS

One hundred forty-three patients with stage T1 NSCLC underwent both helical dynamic CT and integrated PET/CT followed by surgical nodal staging. In helical dynamic CT, patients were regarded to have stage N2 disease when a nodule showed a peak enhancement > or = 110 H or a net enhancement > or = 60 H. In integrated PET/CT, nodes were regarded as positive for malignancy when they showed > or = 3.5 in maximum standardized uptake value with a discrete margin and more 18F-FDG uptake than mediastinal structures. Sensitivities, specificities, and accuracies for mediastinal nodal metastasis detection were compared for helical dynamic CT and integrated PET/CT using the McNemar test.

RESULTS

Of the 143 patients, 34 (24%) had positive mediastinal nodes. The sensitivity, specificity, and accuracy for mediastinal nodal metastasis prediction on helical dynamic CT were 65% (22 of 34 patients), 89% (97 of 109), and 83% (119 of 143), respectively, whereas those on integrated PET/CT were 56% (19 of 34), 100% (109 of 109), and 90% (128 of 143). The p values were 0.664, < 0.001, and 0.015.

CONCLUSION

In stage T1 NSCLC, contrast-enhanced helical dynamic CT better predicts, but not significantly so, mediastinal nodal metastasis than PET/CT, whereas PET/CT shows perfect specificity and higher accuracy than helical dynamic CT.

Для цитирования: Yi Chin A, Lee Kyung Soo, Kim Byung-Tae, Shim Sung Shine, Chung Myung Jin, Sung Yon Mi, Jeong Sun Young. Efficacy of helical dynamic CT versus integrated PET/CT for detection of mediastinal nodal metastasis in non-small cell lung cancer.. AJR. American journal of roentgenology. 2007. DOI: 10.2214/ajr.05.2081.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.