Samaniego Edgar A, Mendez Aldo A, Nguyen Thanh N, Kalousek Vladimir, Guerrero Waldo R, Dandapat Sudeepta, Dabus Guilherme, Linfante Italo, Hassan Ameer E, Drofa Alexander, Kouznetsov Evgueni, Leedahl David, Hasan David, Maud Alberto, Ortega-Gutierrez Santiago

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Complex wide-neck intracranial aneurysms are challenging to treat. We report a multicenter experience using the LVIS Jr stent for "Y-stent"-assisted coiling embolization of wide-neck bifurcation aneurysms.

METHODS

Seven centers provided retrospective data on patients who underwent Y-stenting. Technical complications, immediate posttreatment angiographic results, clinical outcomes, and imaging follow-up were assessed.

RESULTS

Thirty patients/aneurysms were treated: 15 basilar tip, 8 middle cerebral artery, 4 anterior communicating artery, 1 pericallosal, and 2 posterior inferior cerebellar artery aneurysms. The mean aneurysm size was 11 mm and the mean dome-to-neck ratio was 1.3 mm. Twenty-four aneurysms were unruptured and treated electively, and 6 were acutely ruptured. Fifty-eight LVIS Jr stents were successfully deployed without any technical issue. One pro-cedural and transient in-stent thrombosis resolved with the intravenous infusion of a glycoprotein IIb/IIIa inhibitor. Five periprocedural complications (within 30 days) occurred: 2 periprocedural neurological complications (1 small temporal stroke that presented with transient aphasia and 1 posterior cerebral artery infarct) and 3 nonneurological periprocedural complications (2 retroperitoneal hematomas, and 1 patient developed a disseminated intravascular coagulopathy). One permanent complication (3.3%) directly related to Y-stenting was reported in the patient who suffered the posterior cerebral artery infarct. Immediate complete obliteration (Raymond-Roy Occlusion Classification [RROC] I-II) was achieved in 26 cases (89.6%). Twenty-four patients had clinical and imaging follow-up (mean 5.2 months). Complete angiographic occlusion (RROC I-II) was observed in 23 patients (96%). A good functional outcome with a modified Rankin Scale score ≤2 was achieved in 26 cases.

CONCLUSIONS

In this multicenter case series, Y-stent-assisted coiling of wide-neck aneurysms with the LVIS Jr device was feasible and relatively safe. Follow-up imaging demonstrated very low recanalization rates.

Для цитирования: Samaniego Edgar A, Mendez Aldo A, Nguyen Thanh N, Kalousek Vladimir, Guerrero Waldo R, Dandapat Sudeepta, Dabus Guilherme, Linfante Italo, Hassan Ameer E, Drofa Alexander, Kouznetsov Evgueni, Leedahl David, Hasan David, Maud Alberto, Ortega-Gutierrez Santiago. LVIS Jr Device for Y-Stent-Assisted Coil Embolization of Wide-Neck Intracranial Aneurysms: A Multicenter Experience.. Interventional neurology. 2018. DOI: 10.1159/000487545.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.