MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mog.0b013e32833aaf61

Медицинская библиотека · Current opinion in gastroenterology · 2010

Has high-resolution manometry changed the approach to esophageal motility disorders?

Bansal Ajay, Kahrilas Peter J

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАОбзорПеревод пока не подготовлен

Аннотация

PURPOSE OF REVIEW: High-resolution manometry (HRM) coupled with high-resolution esophageal topography plots (HREPT) has dramatically changed the paradigm of manometric studies. The purpose of the current review is to discuss the salient advantages of HRM that are likely to change the clinical practice of manometry.

RECENT FINDINGS: Recent studies evaluating HRM suggest a significant improvement in the sensitivity for the diagnosis of achalasia when compared with conventional manometry. By reproducibly subtyping achalasia into classic achalasia, achalasia with pressurization, or spastic achalasia with differential responses to treatment, HRM has potential to predict clinical outcomes. Preliminary observations with HRM suggest that much of what was labeled distal esophageal spasm is in fact achalasia with esophageal compression and pseudorelaxation, or spastic achalasia. HRM is capable of selectively analyzing discrete esophagogastric junction contributors (lower esophageal sphincter and crural diaphragm) during deglutitive relaxation to clearly identify the site of abnormally high outflow resistance. HRM has improved the recognition of a clinically heterogeneous entity called functional obstruction with potential for directed therapy.

SUMMARY: Improved, accurate and reproducible recognition of manometric diagnoses by HRM will allow the clinician to confidently diagnose esophageal disorders such as achalasia, direct therapy and predict outcomes.

Для цитирования: Bansal Ajay, Kahrilas Peter J. Has high-resolution manometry changed the approach to esophageal motility disorders?. Current opinion in gastroenterology. 2010. DOI: 10.1097/mog.0b013e32833aaf61.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.