Evaluating calf bioimpedance measurements for fluid overload management in a controlled environment.

Delano Maggie, Sodini Charles

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the relationship between calf bioimpedance measurements and fluid removal in a controlled environment (hemodialysis) as a first step toward using these measurements for remote congestive heart failure (CHF) monitoring.

APPROACH: Calf bioimpedance measurements were recorded in 17 patients undergoing hemodialysis (9/17 (53%) CHF, 5/17 (30%) female). Measurements were performed before and after hemodialysis. Additional parameters related to hemodialysis and patient fluid status such as estimated dry weight were also recorded.

MAIN

RESULTS

Calf bioimpedance changes depended on calf fluid status as assessed by calf normalized resistivity (CNR). Patients with lower calf fluid overload (as assessed by CNR greater than [Formula: see text] [Formula: see text]m[Formula: see text] kg[Formula: see text]) had larger decreases in calf fluid than patients with higher calf fluid overload. High CNR patients had fluid changes within the calf that depended on the ultrafiltration rate, with patients with lower ultrafiltration rates experiencing fluid shifts from extracellular to intracellular fluid. Additionally, there were correlations between changes in calf extra-, intra- and total- water and the ultrafiltration volume removed for high CNR patients ([Formula: see text], respectively, all p-values [Formula: see text] 0.05).

SIGNIFICANCE: These results suggest that while the relationship between calf fluid status and total fluid status is complex, changes in calf volumes comparable to those expected in an ambulatory setting are measurable and relate to changes in total volume. This suggests that calf bioimpedance measurements for CHF remote monitoring warrant future investigation, as remote fluid status management could reduce fluid overload related hospitalizations in CHF patients.

Для цитирования: Delano Maggie, Sodini Charles. Evaluating calf bioimpedance measurements for fluid overload management in a controlled environment.. Physiological measurement. 2018. DOI: 10.1088/1361-6579/aaf277.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.