Continuous Renal Replacement Therapy Applications on Extracorporeal Membrane Oxygenation Circuit.

Yetimakman Ayse Filiz, Tanyildiz Murat, Kesici Selman, Kockuzu Esra, Bayrakci Benan

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIMS: Continuous venovenous hemofiltration or hemodiafiltration is used frequently in pediatric patients, but experience of continuous renal replacement therapy (CRRT) application on extracorporeal membrane oxygenation (ECMO) circuit is still limited. Among several methods used for applying CRRT on ECMO patients, we aim to share our experience on inclusion of a CRRT device in the ECMO circuit which we believe is easier and safer to apply.

MATERIALS AND

METHODS

The data were collected on demographics, outcomes, and details of the treatment of ECMO patients who had CRRT. During the study period of 3 years, venous cannula of ECMO circuit before pump was used for CRRT access for both the filter inlet and outlet of CRRT machine to minimize the thromboembolic complications. The common indication for CRRT was fluid overload.

RESULTS

CRRT was used in 3.68% of a total number of patients admitted and 43% of patients on ECMO. The patients have undergone renal replacement therapy for periods of time ranging between 24 h and 25 days (260 h mean). The survival rate of this group of patients with multiorgan failure was 33%. Renal recovery occurred in all of the survivors. Complications such as electrolyte imbalance, hypothermia, and bradykinin syndrome were easily managed.

CONCLUSIONS

Adding a CRRT device on ECMO circuit is a safe and effective technique. The major advantages of this technique are easy to access, applying CRRT without extra anticoagulation process, preventing potential hemodynamic disturbances, and increased clearance of solutes and fluid overload using larger hemofilter.

Для цитирования: Yetimakman Ayse Filiz, Tanyildiz Murat, Kesici Selman, Kockuzu Esra, Bayrakci Benan. Continuous Renal Replacement Therapy Applications on Extracorporeal Membrane Oxygenation Circuit.. Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine. 2017. DOI: 10.4103/ijccm.ijccm_128_17.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.