MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1253/circj.cj-24-0589

Медицинская библиотека · Circulation journal : official journal of the Japanese Circulation Society · 2025

Impact of Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stents in Percutaneous Coronary Intervention for Hemodialysis Patients.

Taninobu Narumi, Kubo Shunsuke, Oka Satoki, Nishiura Naoki, Sasaki Kenta, Matsushita Shunsuke, Mushiake Kazunori, Shima Yuki, Ikuta Akihiro, Osakada Kohei, Sawayama Yuichi, Tada Takeshi, Fuku Yasushi, Tanaka Hiroyuki, Kadota Kazusige

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Hemodialysis (HD) is associated with adverse cardiovascular events after percutaneous coronary intervention (PCI). Although the ultrathin strut biodegradable polymer sirolimus-eluting stent (ultrathin strut BP-SES) has had better results in patients undergoing PCI compared with other drug-eluting stents (DES), its usefulness in HD patients is unknown.

METHODS AND

RESULTS

This study involved 286 lesions in 162 HD patients who underwent PCI with a DES between January 2018 and June 2022. The incidence of clinically driven target lesion revascularization (TLR), target vessel failure (TVF: cardiac death, target vessel MI and clinically driven target vessel revascularization [TVR]) was assessed. During a median 636 days, clinically driven TLR occurred in 32 lesions. Clinically driven TLR at 2 years was significantly lower in the ultrathin strut BP-SES group than in the other DES group (2.9% vs. 17.3%, log-rank P=0.028). TVF occurred in 43 patients. The cumulative incidence of TVF was not different between two groups; however, clinically driven TVR was significantly lower in patients treated with the ultrathin strut BP-SES than with other DES (4.5% vs. 25.7%, log-rank P=0.027). In the quantitative coronary angiography analysis, late lumen loss at follow-up was significantly smaller in the ultrathin strut BP-SES group (0.13±0.40 vs. 0.67±1.02 mm, P<0.001).

CONCLUSIONS

In patients on HD undergoing PCI, the incidence of clinically driven TLR was significantly lower in ultrathin strut BP-SES compared to other DES.

Для цитирования: Taninobu Narumi, Kubo Shunsuke, Oka Satoki, Nishiura Naoki, Sasaki Kenta, Matsushita Shunsuke, Mushiake Kazunori, Shima Yuki, Ikuta Akihiro, Osakada Kohei, Sawayama Yuichi, Tada Takeshi, Fuku Yasushi, Tanaka Hiroyuki, Kadota Kazusige. Impact of Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stents in Percutaneous Coronary Intervention for Hemodialysis Patients.. Circulation journal : official journal of the Japanese Circulation Society. 2025. DOI: 10.1253/circj.cj-24-0589.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.