OBJECTIVES

Central venous catheters (CVCs) are vital for treating ICU patients. However, up to a quarter of CVCs fail from mechanical or infective complications. Poor securement of CVCs to the skin contributes to catheter failure, particularly CVCs placed in the jugular vein, which are highly vulnerable to pullout forces. This study evaluated the effectiveness of medical liquid adhesive (MLA) for improving jugular CVC dressing adhesion.

DESIGN

Multisite parallel group, superiority, randomized controlled trial.

SETTING

Four metropolitan Australian ICUs.

PATIENTS: Eligible patients were 18 years old or older, within 12 hours of jugular CVC insertion, expected to need the CVC for greater than or equal to 72 hours, and remain in ICU for greater than or equal to 24 hours.

INTERVENTIONS: Patients were randomly allocated (stratified by hospital and gender) to standard CVC dressings with the application of MLA to skin under the dressing border (intervention) or standard care CVC dressings (control).

MEASUREMENTS AND MAIN

RESULTS

The primary endpoint was dressing failure within 7 days due to lifting edges. Secondary outcomes included the total number of dressing changes, skin injury, and CVC failure. In total, 160 participants (82 control; 78 intervention) were enrolled. There were 22 (28%) and 41 (50%) cases of premature dressing failure in the intervention and control groups respectively (odds ratio, 0.39; 95% CI, 0.20-0.76; p = 0.005). The intervention group had fewer dressing changes (incidence rate ratio [IRR], 0.74; 95% CI, 0.55-0.99). Time to dressing failure (log-rank test; p = 0.12) and all-cause CVC failure (IRR, 1.44; 95% CI, 0.36-5.79) did not differ between groups. Three skin injuries occurred: one in the intervention (blister) and two in the control (maceration and skin tear) groups.

CONCLUSIONS

MLA is associated with significantly decreased jugular CVC dressing failure and longer dressing dwell, with an acceptable safety profile. MLA should be considered to preserve jugular CVC dressings in ICU.

Для цитирования: Marsh Nicole, O'Brien Catherine, Larsen Emily N, Alexandrou Evan, Ware Robert S, Pearse India, Coyer Fiona, Patel Maharshi S, Royle Ruth H, Rickard Claire M, Sosnowski Kellie, Harris Patrick N A, Laupland Kevin B, Bauer Michelle J, Fraser John F, McManus Craig, Byrnes Joshua, Corley Amanda. Securing Jugular Central Venous Catheters With Dressings Fixed to a Liquid Adhesive to Prevent Dressing Failure in Intensive Care Patients (the STICKY Trial): A Randomized Controlled Trial.. Critical care medicine. 2025. DOI: 10.1097/ccm.0000000000006533.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.