MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/eurheartj/ehaf098

Медицинская библиотека · European heart journal · 2025

Titanium-nitride-oxide-coated vs. drug-eluting stents in acute coronary syndromes: an individual patient data meta-analysis.

Mahendiran Thabo, Bouisset Frederic, Tonino Pim, Pijls Nico H J, Sia Jussi, Kervinen Kari, Rivero-Crespo Fernando, Jüni Peter, Roza da Costa Bruno, Collet Carlos, Mizukami Takuya, Karjalainen Pasi, De Bruyne Bernard

СтатьяМетаанализСистематический обзорСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIMS: In acute coronary syndromes (ACS), vascular healing at the site of implantation of drug-eluting stents (DES) can be delayed. Titanium-nitride-oxide-coated stents (TiNOS) demonstrate faster strut coverage without the excessive intimal hyperplasia observed with bare metal stents. The 5-year outcomes of patients presenting with ACS, randomized to receive either TiNOS or DES, were compared.

METHODS

A systematic review and individual participant data meta-analysis of trials comparing TiNOS with DES for the treatment of ACS was conducted (PROSPERO: CRD42024514342). The primary endpoint was major adverse cardiac events (MACE) at 5 years, a composite of cardiac death (CD), myocardial infarction (MI), and ischaemia-driven target lesion revascularization (TLR). Pre-specified secondary endpoints included CD, MI, TLR, and stent thrombosis. Data were pooled using a mixed-effects Cox regression model with random slope and stratified baseline hazards.

RESULTS

Patient-level data (n = 2743) were obtained from three randomized controlled trials (TiNOS: n = 1620 vs. DES: n = 1123). After a median follow-up of 4.93 years, there was no significant difference in the primary endpoint between TiNOS and DES (12.6% vs. 16.2%; hazard ratio [HR] .82, 95% confidence interval [CI] .67-1.00, P = .051), mainly due to a similar rate of TLR (8.0% vs. 8.1%; HR 1.05, 95% CI .80-1.38, P = .733). However, TiNOS was associated with significantly lower rates of CD (1.5% vs. 3.7%; HR .46, 95% CI .26-.81, P = .007), MI (5.2% vs. 9.6%; HR .56, 95% CI .42-.75, P < .001), and stent thrombosis (1.1% vs. 3.8%; HR .30, 95% CI .17-.53, P < .001).

CONCLUSIONS

In ACS patients, TiNOS was associated with similar rates of MACE and TLR as compared with DES but significantly lower rates of CD, MI, and stent thrombosis.

Для цитирования: Mahendiran Thabo, Bouisset Frederic, Tonino Pim, Pijls Nico H J, Sia Jussi, Kervinen Kari, Rivero-Crespo Fernando, Jüni Peter, Roza da Costa Bruno, Collet Carlos, Mizukami Takuya, Karjalainen Pasi, De Bruyne Bernard. Titanium-nitride-oxide-coated vs. drug-eluting stents in acute coronary syndromes: an individual patient data meta-analysis.. European heart journal. 2025. DOI: 10.1093/eurheartj/ehaf098.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.