Clinically relevant haemolysis after transcatheter aortic valve implantation with new-generation balloon-expandable valve.

Higuchi Ryosuke, Takamisawa Itaru, Kitamura Mitsunobu, Nanasato Mamoru, Ohno Makoto, Isobe Mitsuaki

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Valve-related haemolysis is a known complication following prosthetic valve surgery. Haemolysis after transcatheter aortic valve implantation (TAVI) has been reported in some studies, all of which were non-critical. Data related to haemolysis associated with new-generation balloon-expandable valve (BEV) are scarce.

METHODS

Among 441 patients who underwent TAVI between April 2023 and June 2024, 282 patients treated with new-generation BEV were analysed. Haemolysis was defined based on the lactate dehydrogenase, haemoglobin, reticulocyte and haptoglobin levels. Clinically relevant haemolysis was defined as a case requiring transfusion and/or reintervention.

RESULTS

Clinically relevant haemolysis occurred in 6 of 282 patients (2.1%), with median age of 84 years. Three (50%) received a 20 mm valve, and the oversizing ranged from -6.6% to +2.7%. All patients (100%) exhibited paravalvular leakage at the native commissural sites, with moderate or greater paravalvular leakage in two (33%). Lactate dehydrogenase levels exceeded 1200 IU/L in five (83%), four (67%) required transfusion and three (50%) underwent reintervention: balloon aortic valvuloplasty in one and valve-in-valve procedures in two. Haemolysis regressed in three reintervention cases; however, one patient died 9 days postoperatively due to COVID-19. Among three patients (50%) managed conservatively, one developed prosthetic valve endocarditis, whereas another showed spontaneous regression of haemolysis. Over a median follow-up of 218 days, five patients (83%) survived.

CONCLUSION

Clinically relevant haemolysis occurred in 2.1% of patients undergoing TAVI with new-generation BEV, with 67% requiring transfusion and 50% undergoing reintervention. Further research is warranted to identify risk factors and optimise management strategies for haemolysis.

Для цитирования: Higuchi Ryosuke, Takamisawa Itaru, Kitamura Mitsunobu, Nanasato Mamoru, Ohno Makoto, Isobe Mitsuaki. Clinically relevant haemolysis after transcatheter aortic valve implantation with new-generation balloon-expandable valve.. Open heart. 2025. DOI: 10.1136/openhrt-2024-003112.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.