Trends in utilization and clinical outcomes with and without the use of distal filter wire embolic protection devices.

Scully Timothy G, Roberts Louise, Dinh Diem, Brennan Angela, Clark David, Ajani Andrew, Reid Christopher M, Oqueli Ernesto, Hiew Chin, Stub Dion, Chandrasekhar Jaya, Freeman Melanie

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Embolic protection devices were developed to reduce the risk of common complications encountered during percutaneous coronary intervention (PCI) of saphenous vein grafts, however, in the setting of contemporary multi-modality medical management, their overall efficacy has been called into question. This study aimed to assess the evolving utilization and clinical outcomes associated with distal filter wire embolic protection devices in saphenous vein PCI.

METHODS

Consecutive patients undergoing PCI to a saphenous vein graft in a registry were included. Peri-procedural and long-term outcomes including 12-month mortality and 30-day MACCE rates were compared between PCI using a distal filter wire embolic protection device and unprotected PCI.

RESULTS

From 2005 to 2020, a total of 753 patients underwent PCI to a saphenous vein graft with 256 using a distal filter wire embolic protection device. At one year, the use of a distal filter wire embolic protection devices was not associated with a decrease in mortality (4.7 % vs 5.4 %, p = 0.19) and there was no difference in 30-day MACCE rates between protected and unprotected saphenous vein PCI (3.1 % vs 5.8 %, p = 0.10).

CONCLUSION

In this 12-month analysis of saphenous vein graft PCI, there was no evidence that distal filter wire embolic protection devices improved short term post procedural or long-term mortality outcomes.

Для цитирования: Scully Timothy G, Roberts Louise, Dinh Diem, Brennan Angela, Clark David, Ajani Andrew, Reid Christopher M, Oqueli Ernesto, Hiew Chin, Stub Dion, Chandrasekhar Jaya, Freeman Melanie. Trends in utilization and clinical outcomes with and without the use of distal filter wire embolic protection devices.. Cardiovascular revascularization medicine : including molecular interventions. 2024. DOI: 10.1016/j.carrev.2024.10.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.