MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/alr.22451

Медицинская библиотека · International forum of allergy & rhinology · 2019

Development and validation of a preclinical model for training and assessment of cerebrospinal fluid leak repair in endoscopic skull base surgery.

Mattavelli Davide, Ferrari Marco, Rampinelli Vittorio, Schreiber Alberto, Buffoli Barbara, Deganello Alberto, Rodella Luigi F, Fontanella Marco M, Nicolai Piero, Doglietto Francesco

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Achieving an effective endoscopic skull base reconstruction in case of large dural defects requires specific training and can be extremely challenging. The aim of this study was to describe the development and validation of a preclinical model for cerebrospinal fluid (CSF) leak repair, which can be used for training and to test the mechanical efficacy of endoscopic skull base reconstruction.

METHODS

Eleven fresh-frozen cadaver heads were dissected. A catheter was inserted in the subdural space via a cervical access, which was sealed with mastic; a vertical graduated tube connected to the catheter measured intracranial pressure (ICP), while stained water was injected intracranially. After endoscopic skull base reconstruction was performed, an expert surgeon assessed its efficacy. ICP was then gradually increased until a leak was evident and CSF leak pressure value was recorded. The correlation between subjective and quantitative evaluations was investigated through Pearson and Spearman correlation tests.

RESULTS

The model was successfully tested in 11 specimens. A single, large dural defect was created in each model (transplanum-transtuberculum = 4; transplanum-transtuberculum-transsellar = 3; transclival = 3; transcribriform-transplanum = 1). Skull base reconstruction always comprised a rigid buttress with temporal fascia and/or fat. The CSF leak pressure ranged from 4 to 110 cmH2 O. The correlation between expert subjective and quantitative assessment of skull base reconstruction mechanical efficacy was high (r = 0.7; rs = 0.7; p = 0.010 and p = 0.006, respectively).

CONCLUSION

This preclinical model is simple, easily reproducible, and effective in simulating an intraoperative leak and objectively measures the CSF leak pressure point of a skull base reconstruction.

Для цитирования: Mattavelli Davide, Ferrari Marco, Rampinelli Vittorio, Schreiber Alberto, Buffoli Barbara, Deganello Alberto, Rodella Luigi F, Fontanella Marco M, Nicolai Piero, Doglietto Francesco. Development and validation of a preclinical model for training and assessment of cerebrospinal fluid leak repair in endoscopic skull base surgery.. International forum of allergy & rhinology. 2019. DOI: 10.1002/alr.22451.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.