A Fully Automated 3D In-Vivo Delineation and Shape Parameterization of the Human Lamina Cribrosa in Optical Coherence Tomography.

Syga Piotr, Sieluzycki Cezary, Krzyzanowska-Berkowska Patrycja, Iskander D Robert

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

A fully automated method for delineation of the lamina cribrosa in optical coherence tomography (OCT) is proposed. It assesses the three-dimensional (3D) shape of the lamina cribrosa in-vivo, based on a series of OCT B-scans.

METHODS

The algorithm has several image processing steps and it is based on active contour detection performed along three orthogonal directions of the B-scan data cuboid. Further, the delineated 3D lamina cribrosa shape is parameterized with a fourth-order polynomial of two variables [Formula: see text] using the least-squares method. Datasets from a total of 255 subjects from three groups were analyzed: 92 primary open angle glaucoma patients, 77 glaucoma suspects, and 86 controls.

RESULTS

Statistically significant differences were found in the coefficients of monomials xiyj, with both i and j even, between patients and controls and between suspects and controls.

CONCLUSIONS

From the data obtained, it can be concluded that the mean shape parameterization of the lamina cribrosa of glaucoma suspects has similar appearance to that of glaucoma patients but it is markedly different from that of healthy controls.

SIGNIFICANCE: The proposed algorithm enables automatically estimating, for the first time, the lamina cribrosa in 3D, further providing clinicians with a time-efficient discrimination tool supporting glaucoma diagnosis.

Для цитирования: Syga Piotr, Sieluzycki Cezary, Krzyzanowska-Berkowska Patrycja, Iskander D Robert. A Fully Automated 3D In-Vivo Delineation and Shape Parameterization of the Human Lamina Cribrosa in Optical Coherence Tomography.. IEEE transactions on bio-medical engineering. 2018. DOI: 10.1109/tbme.2018.2873893.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.