Comparison of two analytical platforms for quantification of neuroglial biomarkers in blood samples: a single molecule array and an electrochemiluminescence assay.

Aulin Julia, Al-Grety Asma, Sjölin Karl, Erngren Ida, Larsson Anders, Svenningsson Anders, Kultima Kim, Burman Joachim

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Advances in ultrasensitive immunoassays have enabled reliable quantification of neuroglial biomarkers in blood, providing valuable insights into neurological disorders. However, cross-platform evaluations are necessary to ensure comparability and standardization. This study aimed to compare the analytical performance of a Single Molecule Array (Simoa) and an ultrasensitive electrochemiluminescence (ECL) assay for quantifying neurofilament light chain (NfL) and glial fibrillary acidic protein (GFAP) in human serum. Baseline serum samples from 174 participants in the RIFUND trial were analyzed in parallel on both platforms. Concentrations of NfL and GFAP were compared using Spearman correlation, Bland-Altman analyses, reproducibility assessments, dilution linearity, and cross-platform recovery. All samples were quantifiable on both platforms. NfL concentrations correlated strongly between methods (Spearman correlation r = 0.88, p < 0.0001), whereas GFAP correlated moderately (r = 0.77, p < 0.0001). Inter- and intra-assay coefficients of variation were comparable between platforms for both analytes. The relationship between the two assays could be described with the following equations: NfLECL = 7.63 × NfLSIMOA + 1.71 and GFAPECL = 0.332 × GFAPSIMOA + 4.22. Dilution linearity was excellent on both platforms (R2 > 0.99), although cross-platform recovery varied systematically across the analytical range. Both Simoa and ECL demonstrated strong analytical performance for neuroglial biomarker quantification in serum. Despite systematic differences in absolute concentrations, relative agreement was high, particularly for NfL. These findings highlight the need for platform harmonization and provide empirically derived conversion factors to support analytical comparability in research and clinical applications.

Для цитирования: Aulin Julia, Al-Grety Asma, Sjölin Karl, Erngren Ida, Larsson Anders, Svenningsson Anders, Kultima Kim, Burman Joachim. Comparison of two analytical platforms for quantification of neuroglial biomarkers in blood samples: a single molecule array and an electrochemiluminescence assay.. Scientific reports. 2026. DOI: 10.1038/s41598-026-56794-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.