MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2018.07.005

Медицинская библиотека · American journal of ophthalmology · 2018

Use of Machine Learning on Contact Lens Sensor-Derived Parameters for the Diagnosis of Primary Open-angle Glaucoma.

Martin Keith R, Mansouri Kaweh, Weinreb Robert N, Wasilewicz Robert, Gisler Christophe, Hennebert Jean, Genoud Dominique, Research Consortium

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To test the hypothesis that contact lens sensor (CLS)-based 24-hour profiles of ocular volume changes contain information complementary to intraocular pressure (IOP) to discriminate between primary open-angle glaucoma (POAG) and healthy (H) eyes.

DESIGN

Development and evaluation of a diagnostic test with machine learning.

METHODS

Subjects: From 435 subjects (193 healthy and 242 POAG), 136 POAG and 136 age-matched healthy subjects were selected. Subjects with contraindications for CLS wear were excluded.

PROCEDURE: This is a pooled analysis of data from 24 prospective clinical studies and a registry. All subjects underwent 24-hour CLS recording on 1 eye. Statistical and physiological CLS parameters were derived from the signal recorded. CLS parameters frequently associated with the presence of POAG were identified using a random forest modeling approach.

MAIN OUTCOME MEASURES: Area under the receiver operating characteristic curve (ROC AUC) for feature sets including CLS parameters and Start IOP, as well as a feature set with CLS parameters and Start IOP combined.

RESULTS

The CLS parameters feature set discriminated POAG from H eyes with mean ROC AUCs of 0.611, confidence interval (CI) 0.493-0.722. Larger values of a given CLS parameter were in general associated with a diagnosis of POAG. The Start IOP feature set discriminated between POAG and H eyes with a mean ROC AUC of 0.681, CI 0.603-0.765. The combined feature set was the best indicator of POAG with an ROC AUC of 0.759, CI 0.654-0.855. This ROC AUC was statistically higher than for CLS parameters or Start IOP feature sets alone (both P < .0001).

CONCLUSIONS

CLS recordings contain information complementary to IOP that enable discrimination between H and POAG. The feature set combining CLS parameters and Start IOP provide a better indication of the presence of POAG than each of the feature sets separately. As such, the CLS may be a new biomarker for POAG.

Для цитирования: Martin Keith R, Mansouri Kaweh, Weinreb Robert N, Wasilewicz Robert, Gisler Christophe, Hennebert Jean, Genoud Dominique, Research Consortium. Use of Machine Learning on Contact Lens Sensor-Derived Parameters for the Diagnosis of Primary Open-angle Glaucoma.. American journal of ophthalmology. 2018. DOI: 10.1016/j.ajo.2018.07.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.