DOI 10.1016/j.jcrs.2017.10.039

Медицинская библиотека · Journal of cataract and refractive surgery · 2018

Trabecular microbypass stents as minimally invasive approach after conventional glaucoma filtration surgery.

Macher Thomas, Häberle Heike, Wächter Juliane, Thannhäuser Carsten, Aurich Henning, Pham Duy-Thoai

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate long-term efficacy and safety of 2 trabecular microbypass stents in patients with advanced primary open-angle glaucoma (POAG) and insufficient intraocular pressure (IOP) after previous filtration surgery.

SETTING

Vivantes Klinikum Neukölln, Augenklinik, Berlin, Germany.

DESIGN

Retrospective case series.

METHODS

Eyes with uncontrolled and advanced POAG since 2014 were assessed. All eyes previously had at least 1 filtration surgery procedure. The anatomical landmarks and configuration of the anterior chamber angle had to be identified easily. Two iStents were placed nasally into Schlemm canal.

RESULTS

The study comprised 42 patients (42 eyes); 18 eyes had 1 previous glaucoma filtration surgery. During the follow-up of 12 months, the mean IOP in cases of primary failure of filtration surgery decreased from preoperative 23.8 mm Hg ± 3.9 (SD) to 15.2 ± 2.7 mm Hg. For cases with more than 1 previous filtration surgery, the mean IOP decreased from preoperative 26.1 ± 5.7 mm Hg to 16.3 ± 3.3 mm Hg. Medications were reduced from 2.7 ± 0.9 to 2.0 ± 1.1. No intraoperative or perioperative complications occurred.

CONCLUSIONS

For eyes with previous filtration surgery and medically uncontrolled IOP, the implantation of 2 stents provided a minimally invasive and safe reduction of mean IOP to less than 18 mm Hg at 12 months. The number of medications was also reduced.

Для цитирования: Macher Thomas, Häberle Heike, Wächter Juliane, Thannhäuser Carsten, Aurich Henning, Pham Duy-Thoai. Trabecular microbypass stents as minimally invasive approach after conventional glaucoma filtration surgery.. Journal of cataract and refractive surgery. 2018. DOI: 10.1016/j.jcrs.2017.10.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.