Медицинская библиотека · JACC. Cardiovascular interventions · 2015

Transcatheter Aortic and Mitral Valve-in-Valve Implantation for Failed Surgical Bioprosthetic Valves: An 8-Year Single-Center Experience.

Ye Jian, Cheung Anson, Yamashita Michael, Wood David, Peng Defen, Gao Min, Thompson Christopher R, Munt Brad, Moss Robert R, Blanke Philipp, Leipsic Jonathon, Dvir Danny, Webb John G

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

We report our 8-year experience in transcatheter aortic and mitral valve-in-valve (VinV) implantation.

BACKGROUND

Feasibility and good early outcomes associated with transcatheter aortic and mitral VinV implantation into failed surgical bioprostheses have been confirmed, but the mid-term and long-term outcomes of transcatheter aortic and mitral VinV is unknown.

METHODS

A total of 73 patients with aortic (n = 42) and mitral (n = 31) bioprosthetic valve dysfunction underwent transcatheter VinV implantation between April 2007 and December 2013. Edwards balloon-expandable transcatheter valves (Edwards Lifesciences Inc., Irvine, California) were used. Median follow-up was 2.52 years with a maximum of 8 years.

RESULTS

Seventy-two patients (mean age 79.7 ± 9.4 years, 32 women) underwent successful VinV implantation (success rate 98.6%). At 30 days, all-cause mortality was 1.4%, disabling stroke 1.4%, life-threatening bleeding 4.1%, acute kidney injury requiring hemodialysis 2.7%, and coronary artery obstruction requiring intervention 1.4%. No patient had greater than mild paravalvular leak. Estimated survival rates were 88.9%, 79.5%, 69.8%, 61.9%, and 40.5% at 1, 2, 3, 4, and 5 years, respectively. The small surgical valve size (19 and 21 mm) was an independent risk factor for reduced survival in aortic VinV patients. At 2-year follow-up, 82.8% of aortic and 100% of mitral VinV patients were in New York Heart Association functional class I or II.

CONCLUSIONS

Transcatheter VinV for failed surgical bioprostheses can be performed safely with a high success rate and minimal early mortality and morbidity. Transcatheter VinV provides encouraging mid-term clinical outcomes in this high-risk elderly cohort of patients. Transcatheter VinV is an acceptable alternative therapy for failed aortic or mitral bioprostheses in selected high-risk patients.

Для цитирования: Ye Jian, Cheung Anson, Yamashita Michael, Wood David, Peng Defen, Gao Min, Thompson Christopher R, Munt Brad, Moss Robert R, Blanke Philipp, Leipsic Jonathon, Dvir Danny, Webb John G. Transcatheter Aortic and Mitral Valve-in-Valve Implantation for Failed Surgical Bioprosthetic Valves: An 8-Year Single-Center Experience.. JACC. Cardiovascular interventions. 2015. DOI: 10.1016/j.jcin.2015.08.012.