Routine chest X-ray is not mandatory after fluoroscopy-guided totally implantable venous access device insertion.

Thomopoulos Theodoros, Meyer Jeremy, Staszewicz Wojciech, Bagetakos Ilias, Scheffler Max, Lomessy Antoine, Toso Christian, Becker Christoph D, Morel Philippe

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim of this study is to determine whether systematic postoperative chest X-ray is required after totally implantable venous access port device (TIVAD) placement under fluoroscopic control.

METHODS

A retrospective chart review of all consecutive patients with fluoroscopy-guided TIVAD insertion from July 10, 2009 to April 16, 2012 was conducted at the Geneva University Hospitals (n = 927). Patients with an available postoperative chest X-ray were included, regardless of approach (open or percutaneous) and venous access site (subclavian, cephalic, jugular, etc.). Exclusion criteria were incomplete data and preexisting pneumothorax or hemothorax.

RESULTS

Eight hundred ninety-one patients were included. First-intention venous cutdown was performed in 878 patients (98.5%), with success rates of 79.4% and 88.2% when targeting the left and right cephalic veins, respectively. Percutaneous access was the chosen first-intention procedure for 12 patients (1.3%). Eight-hundred thirty-six (93.8%) insertions were performed only by the open approach and 53 (5.9%) implantations required at least one venous puncture. Two implantations were performed using previous central venous accesses. Immediate complications associated with TIVAD placement and detected on the postoperative chest X-ray consisted of 1 asymptomatic pneumothorax, 1 symptomatic hemothorax, and 2 malpositions of the catheter. One additional pneumothorax was discovered during the first night after TIVAD insertion in a patient who became symptomatic.

CONCLUSIONS

The very low incidence of immediate complications detected by postprocedural chest X-ray suggests that such a control is not mandatory as a routine method after fluoroscopy-guided TIVAD insertion mainly performed by venous cutdown. X-ray should be performed only in cases of clinical suspicion.

Для цитирования: Thomopoulos Theodoros, Meyer Jeremy, Staszewicz Wojciech, Bagetakos Ilias, Scheffler Max, Lomessy Antoine, Toso Christian, Becker Christoph D, Morel Philippe. Routine chest X-ray is not mandatory after fluoroscopy-guided totally implantable venous access device insertion.. Annals of vascular surgery. 2013. DOI: 10.1016/j.avsg.2013.08.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.