Analysis of infection risk following covered stent exclusion of pseudoaneurysms in prosthetic arteriovenous hemodialysis access grafts.

Kim Charles Y, Guevara Carlos J, Engstrom Bjorn I, Gage Shawn M, O'Brien Patrick J, Miller Michael J, Suhocki Paul V, Lawson Jeffrey H, Smith Tony P

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine whether exclusion of pseudoaneurysms with the use of a covered stent in prosthetic arteriovenous (AV) hemodialysis access grafts impacts the incidence of eventual AV graft infection.

MATERIALS AND

METHODS

Review of an interventional radiology database for prosthetic AV graft interventions involving stent deployment anywhere within the AV graft circuit revealed 235 interventions in 174 patients between November 2004 and December 2008. Incidence of AV graft infection was analyzed based on stent type (bare metal vs covered), location, and indication for stent deployment on a per-stent, per-procedure, and per-graft basis.

RESULTS

A total of 16.3% of the stent-implanted AV grafts were eventually surgically excised as a result of graft infection. Covered stents used to treat an intragraft pseudoaneurysm were more commonly associated with subsequent graft infection compared with bare or covered stents deployed within the graft for other reasons: 42.1% versus 18.2% (P = .011). Stents deployed in an intragraft location were also associated with a higher incidence of graft infection compared with those deployed at the venous anastomosis or outflow vein: 26.9% versus 6.9% (P < .001). No significant difference was identified in infection rates between bare and covered stents.

CONCLUSIONS

Covered stent exclusion of intragraft pseudoaneurysms demonstrated a significant correlation with eventual prosthetic AV graft infection.

Для цитирования: Kim Charles Y, Guevara Carlos J, Engstrom Bjorn I, Gage Shawn M, O'Brien Patrick J, Miller Michael J, Suhocki Paul V, Lawson Jeffrey H, Smith Tony P. Analysis of infection risk following covered stent exclusion of pseudoaneurysms in prosthetic arteriovenous hemodialysis access grafts.. Journal of vascular and interventional radiology : JVIR. 2011. DOI: 10.1016/j.jvir.2011.09.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.