MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics14222585

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2024

Artificial Intelligence and Image Analysis-Assisted Diagnosis for Fibrosis Stage of Metabolic Dysfunction-Associated Steatotic Liver Disease Using Ultrasonography: A Pilot Study.

Fujii Itsuki, Matsumoto Naoki, Ogawa Masahiro, Konishi Aya, Kaneko Masahiro, Watanabe Yukinobu, Masuzaki Ryota, Kogure Hirofumi, Koizumi Norihiro, Sugitani Masahiko

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/

OBJECTIVES

Elastography increased the diagnostic accuracy of liver fibrosis. However, several challenges persist, including the widespread utilization of equipment, difficulties in measuring certain cases, and the influence of viscosity factors. A rough surface and a blunted hepatic margin have long been acknowledged as valuable characteristics indicative of hepatic fibrosis. The objective of this study was to conduct an image analysis and quantitative assessment of the contour of the sagittal section of the left lobe of the liver.

METHODS

Between February and October 2020, 486 consecutive outpatients underwent ultrasound examinations at our hospital. A total of 214 images were manually annotated by delineating the liver contour to create annotation images. U-Net was employed for liver segmentation, with the dataset divided into training (n = 128), testing (n = 42), and validation (n = 44) subsets. Additionally, 43 Metabolic Dysfunction Associated Steatotic Liver Disease (MASLD) cases with pathology data from between 2015 and 2020 were included. Segmentation was performed using the program developed in the first step. Subsequently, shape analysis was conducted using ImageJ.

RESULTS

Liver segmentation exhibited high accuracy, as indicated by Dice loss of 0.044, Intersection over Union of 0.935, and an F score of 0.966. The accuracy of the classification of the liver surface as smooth or rough via ResNet 50 was 84.6%. Image analysis showed MinFeret and Minor correlated with liver fibrosis stage (p = 0.046, 0.036, respectively). Sensitivity, specificity, and AUROC of Minor for ≥F3 were 0.571, 0.862, and 0.722, respectively, and F4 were 1, 0.600, and 0.825, respectively.

CONCLUSION

Deep learning segmentation of the sagittal cross-sectional contour of the left lobe of the liver demonstrated commendable accuracy. The roughness of the liver surface was correctly judged by artificial intelligence. Image analysis showed the thickness of the left lobe inversely correlated with liver fibrosis stage.

Для цитирования: Fujii Itsuki, Matsumoto Naoki, Ogawa Masahiro, Konishi Aya, Kaneko Masahiro, Watanabe Yukinobu, Masuzaki Ryota, Kogure Hirofumi, Koizumi Norihiro, Sugitani Masahiko. Artificial Intelligence and Image Analysis-Assisted Diagnosis for Fibrosis Stage of Metabolic Dysfunction-Associated Steatotic Liver Disease Using Ultrasonography: A Pilot Study.. Diagnostics (Basel, Switzerland). 2024. DOI: 10.3390/diagnostics14222585.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.