Safety and efficacy of concomitant ablation for atrial fibrillation in rheumatic mitral valve surgery: A meta-analysis.
Аннотация
OBJECTIVES
This review aimed to evaluate the safety and efficacy of concomitant surgical ablation (SA) for patients with atrial fibrillation (AF) undergoing rheumatic mitral valve (MV) surgery.
METHODS
A systematic search of relevant studies focusing on SA for patients with AF undergoing rheumatic MV surgery was performed. The primary outcomes included mortality, efficacy, and complications.
RESULTS
Four randomized controlled trials (RCTs) and four observational studies covering 1931 patients met the inclusion criteria. In RCTs, no significant differences in reoperation for bleeding, low cardiac output syndrome, thromboembolic events, and early (risk ratio [RR], 2.07; 95% confidence intervals [CI], 0.37-11.40; p = .41) and midterm all-cause death (RR, 1.07; 95% CI, 0.40-2.88; p = .89) were noted between the SA group and the nonablation group. These results were similar to those obtained from observational studies. However, ablation was associated with a higher incidence of permanent pacemaker implantation (RR, 2.44; 95% CI, 1.15-5.18; p = .02) in observational studies but not in RCTs (RR, 2.03; 95% CI, 0.19-21.26; p = .56). Furthermore, additional SA was significantly more effective in sinus rhythm (SR) restoration than MV surgery alone at discharge and at the 12-month and 3-year follow-ups.
CONCLUSIONS
Concomitant SA during rheumatic MV surgery does not increase perioperative adverse events. In addition, SA promotes considerable restoration of SR. Although some evidence exists that permanent pacemaker implantation is more common after ablation, not all studies support this notion.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.