Doubly Labeled Water Method and Accelerometer for the Measurement of Energy Expenditure in Human Immunodeficiency Virus-Infected Patients.

Guimarães Mariana P, Ferriolli Eduardo, Pfrimer Karina, Navarro Anderson M

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Several studies have reported increased resting energy expenditure (REE) in human immunodeficiency virus (HIV)-infected patients with HIV-associated lipodystrophy syndrome (HALS). However, limited data exist on the total energy expenditure (TEE). This study was aimed at evaluating the REE and TEE of HIV-infected patients with and without HALS by using the doubly labeled water (DLW) technique and the activity monitor based on accelerometry system (AM), and comparing the results obtained using both methods.

METHODS

Evaluated total of 45 HIV+ men undergoing antiretroviral therapy, including 18 LIPO- (without lipodystrophy) and 27 LIPO+ (with lipodystrophy) individuals were evaluated. Habitual physical activity patterns were measured by using the ActivPAL™ AM system, REE by indirect calorimetry, and TEE by DLW and AM.

RESULTS

No significant differences were found between LIPO- and LIPO+ in REE (1,433 ± 196 vs. 1,510 ± 203 kcal), TEE-DLW (2,691 ± 856 vs. 2,618 ± 415 kcal) and TEE-AM (2,560 ± 458 vs. 2,594 ± 456 kcal), respectively. RQ was a predictor of REE in LIPO+. TEE estimated by the AM had a moderate correlation with DLW, but there was a wide variance in the intra-subject results.

CONCLUSIONS

TEE is not increased in HIV-infected patients with HALS. AM should be used with caution for TEE evaluation during clinical practice.

Для цитирования: Guimarães Mariana P, Ferriolli Eduardo, Pfrimer Karina, Navarro Anderson M. Doubly Labeled Water Method and Accelerometer for the Measurement of Energy Expenditure in Human Immunodeficiency Virus-Infected Patients.. Annals of nutrition & metabolism. 2017. DOI: 10.1159/000458766.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.