MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5664/jcsm.11850

Медицинская библиотека · Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2025

The effect of zolpidem on CPAP acclimatization in patients with OSA: a crossover, randomized, double-blinded, placebo-controlled trial.

Pisalnoradej Piyakorn, Banhiran Wish, Kasemsuk Navarat

Клиническое исследование IV фазыСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

STUDY

OBJECTIVES

To evaluate the short-term effect of zolpidem on continuous positive airway pressure (CPAP) acclimatization in patients with obstructive sleep apnea compared with placebo.

METHODS

This randomized, double-blind, placebo-controlled crossover trial enrolled CPAP-naive patients with obstructive sleep apnea who had an indication for CPAP therapy. Participants were randomly assigned to receive either zolpidem 10 mg or an identical placebo capsule, administered 30 minutes before bedtime for 1 week. In the second week, they crossed over to the alternate treatment. A 24-hour washout period separated the 2 treatment phases.

RESULTS

Twenty-eight participants (mean age, 54.5 ± 13.7 years; 57.1% male) completed the study. The mean CPAP usage per night did not differ significantly between zolpidem and placebo (mean difference, 0.18; 95% confidence interval, -0.39 to 0.75). The percentage of nights with CPAP use ≥ 4 hours also showed no significant difference (mean difference, 2.60; 95% confidence interval, -5.65 to 10.87). Treatment sequence did not affect CPAP adherence (P = .87). Subgroup analyses by sex, disease severity, and arousal index revealed no significant impact of zolpidem on adherence. No serious adverse events were reported, and the most common minor adverse event was dizziness (7.14%).

CONCLUSIONS

Short-term zolpidem use did not improve CPAP adherence during the acclimatization period. These findings underscore the importance of employing multiple acclimatization strategies rather than relying on routine zolpidem use. Larger-scale studies with extended follow-up are warranted to confirm these results.

CLINICAL TRIAL REGISTRATION: Registry: ClinicalTrials.gov; Name: Zolpidem on CPAP Acclimatization in OSA; URL: https://clinicaltrials.gov/study/NCT06084130; Identifier: NCT06084130.

CITATION: Pisalnoradej P, Banhiran W, Kasemsuk N. The effect of zolpidem on CPAP acclimatization in patients with OSA: a crossover, randomized, double-blinded, placebo-controlled trial. J Clin Sleep Med. 2025;21(11):1831-1837.

Для цитирования: Pisalnoradej Piyakorn, Banhiran Wish, Kasemsuk Navarat. The effect of zolpidem on CPAP acclimatization in patients with OSA: a crossover, randomized, double-blinded, placebo-controlled trial.. Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine. 2025. DOI: 10.5664/jcsm.11850.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.