Аннотация

PURPOSE: To investigate the relationships among eye dimensions in magnetic resonance imaging (MRI) scans by sex, age, and strabismus type in Japanese patients with acquired strabismus and high myopia.

STUDY

DESIGN

Retrospective clinical case series.

METHODS

We included 58 eyes of 29 patients with acquired strabismus and high myopia (mean age ± standard deviation: 60.2 ± 14.7 years, axial length [AL]: 28.69 ± 2.12 mm). For all eyes, the equatorial diameter of the globe/AL ratio (EAR) and the globe/orbit volume ratio (GOR) were measured using MRI. EAR and GOR values were compared between the following groups: 9 men vs. 20 women; 8 younger (< 56 years) vs. 21 older (≥ 56 years) patients; and non-esotropia strabismus (NES: 7 patients) vs. esotropia (ET: 13 patients) vs. restrictive strabismus (RS: 9 patients) groups.

RESULTS

Female patients had a smaller EAR (0.87 ± 0.07) and larger GOR (0.38 ± 0.04) than male patients (0.92 ± 0.05 and 0.35 ± 0.03, both P < 0.01). Older patients had a smaller EAR (0.87 ± 0.07) than younger ones (0.93 ± 0.04, P < 0.01), without significant differences in GOR. EAR (NES: 0.92 ± 0.06, ET: 0.86 ± 0.06, RS: 0.89 ± 0.09) significantly differed among the three strabismus groups (P = 0.02: post-hoc test: NES vs. ET, P = 0.02; NES vs. RS, P = 0.49; RS vs. ET, P = 0.67), but no significant differences in GOR were found (P = 0.12).

CONCLUSIONS

Among patients with acquired strabismus and high myopia, women, older patients, and those with esotropia exhibit a smaller EAR and longer sphere shape with AL as the major axis. The parameter EAR might be useful for evaluating the pathogenesis of strabismus associated with high myopia.

Для цитирования: Kono Reika, Hamasaki Ichiro, Kishimoto Fumiko, Shimizu Takehiro, Kindo Hiroya, Shibata Kiyo, Morisawa Shin, Morizane Yuki. Relationships among eye dimensions in magnetic resonance images by sex, age, and strabismus type in Japanese patients with acquired strabismus and high myopia.. Japanese journal of ophthalmology. 2024. DOI: 10.1007/s10384-024-01133-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.