MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euaf304

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026

Ablation of atrial fibrillation sources identified through sequential high-density mapping: in silico comparison against anatomy-based approaches.

Gonçalves Marques Victor, Gharaviri Ali, Özgül Ozan, Pezzuto Simone, Auricchio Angelo, Vernooy Kevin, Linz Dominik, Hermans Ben, Bonizzi Pietro, Zeemering Stef, Schotten Ulrich

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation, but recurrences are frequent. Ablating AF sources beyond PVI may prevent re-initiations. This proof-of-principle in silico study compares a novel source-based ablation approach to conventional strategies in preventing AF re-initiation.

METHODS AND

RESULTS

We compared two conventional ablation strategies [PVI and PVI + posterior wall isolation (box ablation)] with our source-based approach. After PVI, a high-density mapping catheter was guided sequentially upstream of local repetitive conduction patterns until a source was identified. Located targets were ablated, connecting them to non-conducting boundaries. Strategies were compared based on their AF re-initiation rates after incremental pacing and ablated and electrically isolated areas. Analyses were performed in seven different scenarios with atria of different sizes, without (n = 3) and with fibrosis (n = 4), to assess different AF progression stages. Compared to no ablation, PVI reduced initiation rates in non-fibrotic atria (23 ± 8% control vs. 15 ± 0% PVI) but was less effective with fibrosis (60 ± 4% vs. 53 ± 10%). Box ablation was not superior to PVI while isolating more of the left atrium (isolated area in PVI: 31.5 ± 0.7% vs. box: 43.6 ± 0.5%). Conversely, source ablation completely prevented AF initiation in all scenarios, achieving comparable left atrial isolation with box ablation (isolated area without fibrosis: 36.3 ± 1.4%; with fibrosis: 43.2 ± 2.6%) and including right atrial lesions. Although macro-re-entrant tachycardias occurred frequently after source ablation, they were terminated with minimal lesions.

CONCLUSION

Ablating AF sources using our high-density mapping approach was more efficient in preventing AF re-initiation in silico than anatomy-based strategies.

Для цитирования: Gonçalves Marques Victor, Gharaviri Ali, Özgül Ozan, Pezzuto Simone, Auricchio Angelo, Vernooy Kevin, Linz Dominik, Hermans Ben, Bonizzi Pietro, Zeemering Stef, Schotten Ulrich. Ablation of atrial fibrillation sources identified through sequential high-density mapping: in silico comparison against anatomy-based approaches.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2026. DOI: 10.1093/europace/euaf304.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.