Do we need to cool the lung graft after ex vivo lung perfusion? A preliminary study.

Stanzi Alessia, Neyrinck Arne, Somers Jana, Cauwenberghs Hans, Verbeken Eric, Santambrogio Luigi, Van Raemdonck Dirk

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

After normothermic ex vivo lung perfusion (EVLP), pulmonary grafts are usually flush-cooled and stored on ice until implantation although evidence for this practice lacks. We compared outcomes between 2 post-EVLP preservation strategies in a porcine left single-lung transplantation model.

MATERIAL AND

METHODS

After cold flush and 2-h EVLP, donor lungs were prepared and split. In [C], (n = 5) lungs cooled on device to 15°C were preserved in ice-water; in [W] (n = 5), lungs were disconnected from EVLP at 37°C and kept at room temperature. The left lung was transplanted in a recipient animal. Posttransplant, 6 h-monitoring included hourly assessment of pulmonary vascular resistance, pulmonary artery pressure, plateau airway pressure, compliance, and oxygenation before and after exclusion of the right lung. Lung biopsies and bronchoscopy with bronchoalveolar lavage (BAL) were performed at retrieval, at the end of EVLP (R lung), and 1 and 6 h after reperfusion (L lung).

RESULTS

Lungs in [W] showed the highest compliance (P < 0.05) and the lowest plateau airway pressure (not statistically significant) throughout the whole reperfusion period. Oxygenation and pulmonary artery pressure were similar between groups. Pulmonary vascular resistance was stable in [C], but rose after reperfusion in [W]. Histologic signs of lung injury and BAL neutrophilia were more pronounced in [C] at 1 h (not statistically significant and P < 0.05, respectively). BAL cytokine levels and lung tissue expression of intercellular adhesion molecule 1 did not differ between groups.

CONCLUSIONS

Normothermic preparation after EVLP results in similar graft performances compared with lung cooling after EVLP.

Для цитирования: Stanzi Alessia, Neyrinck Arne, Somers Jana, Cauwenberghs Hans, Verbeken Eric, Santambrogio Luigi, Van Raemdonck Dirk. Do we need to cool the lung graft after ex vivo lung perfusion? A preliminary study.. The Journal of surgical research. 2014. DOI: 10.1016/j.jss.2014.07.068.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.